New BTO 90-Day Pipe Sweat and Warranty Check Guide

Brief daytime spot checks miss BTO trunking sweat because refrigerant pipes need sustained multi-room loads to drop below dew point. Testing full runtime before carpentry starts preserves clean walls and installer accountability.

On this page

Quick summary

Running all BTO indoor units together for four continuous hours before carpentry begins exposes thin pipe lagging, trunking sweat, and slow PVC drain leaks while installer warranty remains active. Catching dampness early prevents dismantling new wardrobes later.

Send leak photo on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Why Brief Room Checks Miss BTO Trunking Condensation

Installers often switch on one BTO blower for ten minutes right after piping finishes. That brief spot test never chills long multi-room branches deeply enough to expose unsealed foam seams.

Wet skim-coat plaster and fresh paint raise indoor humidity sharply during key-collection weeks. Once every room runs together for several hours, cold unlagged copper turns outer PVC trunking wet.

Waiting until move-in night shifts discovery past standard 90-day defect windows. Hidden moisture behind full-height bedroom wardrobes swells laminates before owners notice drips. Early multi-room testing prevents expensive timber teardown later.

Check Every Trunking Zone During Simultaneous Testing

Shut every flat window and run all indoor units at 19 degrees cool mode for four uninterrupted hours:

Scroll to see more columns

Check every trunking zone during simultaneous testing summary table
BTO checkpointFour-hour load methodExpected pass resultWarranty action step
Corridor PVC trunkingRun fingers and tissue along seamsDry exterior at room temperatureLog cold sweating for re-lagging
Wall sleeves and bendsInspect above pelmet lines by torchNo dark paint patches or streaksClaim foam gap sealing early
Indoor pan and drain teeCheck bottom casing with dry paperZero warm water drops formingFix reverse PVC slope promptly
Floor trap outletObserve yard drain during peak coolingSmooth trickle without gurglingFlush plaster debris before handover

Log Dampness Defects Before Built-In Carpentry Arrives

Perform every inspection from safe indoor floor footing. MOM and BCA rules strictly forbid stepping onto exterior HDB aircon ledges or opening live isolator covers.

Wipe suspect trunking seams with dry tissue. Film continuous date-stamped phone clips whenever cold dampness returns on outer PVC casing.

Check both master and common bathroom floor traps where drain pipes terminate. Watch for standing water or plaster grit blocking outflow. Take clear date-stamped photos before tiles or cabinets cover access points. Send written photo logs to your contractor before wardrobe frames box in corridor trunking.

Verify BTO Repairs and Post-Renovation Cleaning Rates

After defect rectification completes and sanding dust settles, confirm multi-room cooling health before moving furniture inside:

  • Arrange an independent S$30 fault survey if installers dispute sweating lines. Corrective re-lagging or repair work cancels that fee with 30-day cover.
  • Multi-room BTO flats with three or more heads clean at S$25 per head for light general servicing (14-day warranty). Pairs run S$30 each, and one head costs S$50.
  • Renovation paint odours wash out via chemical servicing priced at S$60 per head across three-plus units (60-day warranty). Pairs bill S$70 each, and solo heads cost S$80.
  • Fine plaster powder caked inside blower blades requires dismantled overhauls at S$115 per blower on three-plus BTO bedrooms (90-day warranty). Pairs run S$125 each, and single heads cost S$150.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

How long should new BTO owners run all aircons together before carpentry?
Operating every BTO indoor unit simultaneously at 19 degrees for three to four continuous hours forces full suction flow across all branch pipes. That sustained run exposes hairline insulation gaps and slow condensate drips before wardrobe installers conceal walls.
What causes PVC trunking to sweat in a newly renovated BTO flat?
Trunking condensation starts when humid indoor air contacts cold unsealed copper pipes through thin, split, or loosely taped closed-cell foam lagging. Elevated moisture from curing wall plaster and paint worsens sweating if branches run without airtight foam seams.
Should BTO homeowners inspect outdoor pipes on the aircon ledge directly?
Residents must restrict defect checks to indoor PVC trunking, casing undersides, wall sleeves, and floor-trap drains from safe floor footing. MOM and BCA regulations forbid climbing out windows or stepping onto external HDB aircon ledges.
Why should post-renovation servicing happen before moving furniture into a BTO?
Renovation sawing, tiling, and wall sanding fill indoor mesh screens and blower blades with fine alkaline dust even when units stay covered. Clearing residue before move-in protects drain pans from hardening sludge and maintains quiet airflow.

Sources

Sources checked 27 Nov 2026

  1. HDB Aircon Installation GuidelinesHousing & Development Board (HDB) · Checked 27 Nov 2026
  2. BCA Air-Conditioning Safety GuidanceBuilding and Construction Authority (BCA) · Checked 27 Nov 2026
  3. MOM and BCA Ledge Safety CircularMinistry of Manpower (MOM) and BCA · Checked 27 Nov 2026