Quick summary
Cold bedrooms paired with a warm living room prove your shared compressor still runs properly. The fault usually isolates to a stuck outdoor branch electronic expansion valve, a dust-choked 18,000 BTU wide coil, or strong afternoon open-plan heat gain.
On-site fault check: $30 ($80 VRV), waived if you proceed with repair · See diagnosis & repair
Pinpoint Why Only the Living Room Loses Cooling
Singapore System 3 and System 4 homes link 9,000 BTU bedroom heads and one 18,000 BTU living-room unit to one compressor. Cold bedrooms prove overall system gas pressure is rarely empty.
Failure almost always sits along that living-room branch line or its wide evaporator fins. Kitchen grease, hallway lint, and afternoon sunlight strike living zones hardest.
Compare Branch Valve Faults, Wide Coil Dirt, and Sizing Caps
Tell a jammed outdoor branch valve apart from matted wide-coil dirt or daytime heat gain with four field clues:
Scroll to see more columns
| Living-room clue | Root branch cause | Bedrooms off test | Recommended next step |
|---|---|---|---|
| Room-temp air past clean mesh | Stuck outdoor branch EEV valve | Still lukewarm when run alone | Book S$30 EEV coil resistance check |
| Weak breeze and sour smell | Choked 18,000 BTU coil and wheel | Slightly cooler when run solo | Arrange chemical wash or overhaul |
| Warm at 3 pm, cold past 8 pm | 18k BTU sizing cap under glare | Cools sharply once sun drops | Draw blinds; shut open kitchen doors |
| Ice line along upper coil pipe | Semi-jammed EEV metering pin | Bedrooms chill without icing | Power off; inspect branch valve drive |
Run Safe Indoor Airflow and Load Checks Before Calling a Technician
Turn off all bedroom blowers first. Then run the living-room head alone at 18 degrees on top fan speed for ten minutes. Wash dusty filters indoors and close west-facing curtains to test heat gain.
HDB and MOM rules forbid stepping outside onto ledges to touch branch lines or valve heads. If solo operation stays warm past clean filters, book an electronic expansion valve check.
Schedule a Branch Valve Test or Living Coil Wash
Match your solo test outcome against the right Snowflake flat-rate option below:
- Isolate jammed electronic expansion valve coils or clogged strainers via a S$30 diagnostic visit. Repairs waive that fee and carry 30-day warranty cover.
- Refresh lightly dusted multi-splits with general servicing. Three-plus blowers run S$25 per room, pairs cost S$30 apiece, and one room bills S$50 (14-day warranty).
- Degrease sticky 18,000 BTU coils through chemical servicing. Three or more units run S$60 per room, two cost S$70 each, and one costs S$80 (60-day cover).
- Strip dense cooking slime off large fan wheels with dismantled chemical overhauls. Three-plus coils run S$115 each, pairs cost S$125 each, and solo units cost S$150.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Mitsubishi Electric · Wall-mounted
Warm air with normal gas pressure: fouled coil, not low gas
Grease-choked indoor evaporator coil and dust-packed blower wheel causing poor temperature drop while refrigerant pressure stayed full

Samsung · Wall-mounted
Coastal unit losing gas again: salt ate the pipe fitting
A corroded outdoor fitting thinned past the point where it can seal
Common Questions
Can low refrigerant make only the living room warm while bedrooms stay freezing?
Why does an 18,000 BTU living-room unit feel weak only during afternoon heat?
How do technicians fix a stuck outdoor electronic expansion valve on one branch?
Does running a warm living room alongside cold bedrooms waste SP Group electricity?