PRISM+ PRCN36 carries NEA 5-tick approval ELS-PRS-AC250043 through March 2028, rating 7.4 kW capacity, 5.52 weighted COP, and 2,920 kWh yearly test use. Eligible HDB flats offset purchases with S$400 Climate Vouchers, while SP Group Q4 2026 tariffs put that benchmark at S$910 yearly.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
PRISM+ PRCN36 NEA Efficiency and SP Group Bill Math
Registered under NEA certificate ELS-PRS-AC250043 until 23 March 2028, PRISM+ PRCN36 achieves 5 green ticks. Cooling capacity reaches 7.4 kW. Efficiency ratings stand at 4.87 full-load COP, 5.95 part-load COP, and 5.52 weighted COP.
NEA testing logs 2,920 kWh per year, printed as S$788 on the energy label. SP Group's Q4 2026 GST-inclusive tariff of 31.16 cents/kWh raises that benchmark to S$910 yearly, or roughly S$76 monthly.
Overnight single-bedroom cooling taps the higher 5.95 part-load COP instead of full-load draw. Eligible HDB buyers also redeem S$400 Climate Vouchers until Dec 2027 toward qualifying 5-tick multi-split systems.
Compare PRCN36 Specifications and HDB Sizing Fit
Inspect verified PRCN36 efficiency figures, local running costs, and multi-room sizing notes side by side:
Scroll to see more columns
| PRCN36 ownership metric | Verified listing detail | Published figure | HDB or condo guidance |
|---|---|---|---|
| NEA certificate status | ELS-PRS-AC250043 (5 ticks) | Expires 23 March 2028 | Qualifies for S$400 HDB Climate Vouchers |
| Cooling and COP spread | 7.4 kW multi split | 4.87 full / 5.95 part load | 5.52 weighted COP rewards single-room nights |
| Annual test electricity | 2,920 kWh per year | S$788 label / S$910 SP Q4 | About S$76 monthly under 31.16c billing |
| Typical room pairing | Three-room or compact four-room | 7.4 kW outdoor condenser | Stagger afternoon living and night bedrooms |
Verify HDB Bracket Clearance and Piping Specs Before Install
Sizing a 7.4 kW condenser works best across three bedrooms or staggered four-room HDB layouts. Switching every head on simultaneously during sunny afternoons pushes draw toward 4.87 full-load COP and slows pulldown.
HDB rules mandate BCA-approved stainless brackets on approved exterior supports. Route drains continuously into floor traps. Specify thick copper tubing, closed-cell insulation, and dry nitrogen vacuuming upfront.
Schedule PRCN36 Servicing to Keep Efficiency Steady
Clean evaporator coils preserve PRCN36 airflow and stop condensate trays overflowing during humid Singapore months:
- Diagnostic inspections run S$30 for split setups, while commercial VRV evaluations run S$80. That inspection charge drops off once work proceeds with 30-day repair coverage.
- General upkeep costs S$50 for one PRCN36 blower, or S$30 apiece for two. Three-room and larger bookings bill S$25 each, backed by a 14-day workmanship guarantee.
- Chemical coil treatments cost S$80 for a lone room or S$70 each on two rooms. Homes with three or more heads bill S$60 apiece with 60-day cover.
- Dismantled chemical overhauls clear heavy mould at S$150 for one FCU or S$125 per paired FCU. Three-unit and larger overhauls charge S$115 per drum under 90-day warranty.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Mitsubishi Electric · Multi-split
Outdoor ledge dripping downstairs: split drain pipe stub
Split outdoor PVC condensate drain stub spilling backed-up water across the ledge

Gree · Wall-mounted
Gree F0 on a rusted condenser: refrigerant shortage
R32 refrigerant shortage triggering Gree F0 protection from corroded evaporator return bends
Common Questions
How much electricity does the PRISM+ PRCN36 use yearly in Singapore?
Can HDB owners use S$400 Climate Vouchers for the PRISM+ PRCN36?
Is 7.4 kW enough for four indoor units on a PRISM+ PRCN36?
How often should PRISM+ PRCN36 indoor heads receive chemical servicing?