WSE TKF-100W/BP-M carries NEA 5-tick registration ELS-WSE-AC250011 until 30 January 2028 at 10.21 kW output, 5.63 weighted COP, and 3,942 kWh yearly benchmark draw. Using SP Group's Q4 2026 tariff, that benchmark runs S$1,228 annually, while qualifying HDB homes unlock S$400 Climate Vouchers.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Check TKF-100W/BP-M NEA Benchmarks and SP Group Bills
Listed under NEA certificate ELS-WSE-AC250011 through 30 January 2028, WSE TKF-100W/BP-M hits 5 energy ticks with 10.21 kW total cooling capacity. Rated efficiency stands at 4.90 full-load COP, 6.11 part-load COP, and 5.63 weighted COP.
Annual benchmark consumption measures 3,942 kWh, corresponding to S$1,064 on the standard NEA label. Applying the GST-inclusive 31.16c/kWh late-2026 tariff sets that benchmark at S$1,228 yearly, averaging S$102 monthly.
Peak full-load cooling draws around 2.08 kW of electrical power across living and sleeping zones. Overnight single-room cooling drops output into the higher 6.11 part-load COP range. Careful refrigerant pipe sizing preserves rated capacity across long living-hall piping runs.
Compare TKF-100W/BP-M Capacity Against Large Home Layouts
Review capacity headroom, SP Group bill impact, and property compliance items for TKF-100W/BP-M below:
Scroll to see more columns
| Selection parameter | WSE TKF-100W/BP-M metric | Singapore ownership impact | Required home check |
|---|---|---|---|
| NEA MELS certificate | ELS-WSE-AC250011 (5 ticks) | Valid through 30 January 2028 | Verify serial & label at delivery |
| Simultaneous output | 10.21 kW (~34,800 BTU) | Cools living hall plus bedrooms | Matches 5-room HDB & large condos |
| Annual power benchmark | 3,942 kWh (S$1,064 label) | S$1,228 at 31.16c/kWh tariff | Budget near S$102 monthly use |
| Electrical draw & COP | 4.90 full / 6.11 part COP | ~2.08 kW peak full-load input | Confirm isolator rating via LEW |
| HDB voucher allowance | Eligible 5-tick multi-split | S$400 voucher before Dec 2027 | Check HDB ledge dimensions early |
Confirm Breaker Amperage, Ledge Fit, and Climate Vouchers
Providing roughly 34,800 BTU simultaneous cooling, TKF-100W/BP-M suits Executive HDBs, 5-room flats, and 3-to-4-bedroom condos running open living halls alongside bedrooms. Smaller 3-room flats rarely need 10.21 kW output and run far more smoothly on lighter systems. Oversized condensers cycle off prematurely during light overnight loads.
Have an EMA-licensed electrician check your main DB and isolator amperage before swapping a smaller 7 kW condenser. Measure HDB ledge clearance, specify 22 SWG copper piping, obey MOM and BCA ledge bans, and claim S$400 vouchers before December 2027.
Schedule Regular WSE Upkeep and Diagnostic Inspections
Protect heat-transfer efficiency across high-output coils by matching servicing tiers to your total indoor head count:
- Schedule a S$30 diagnostic check whenever cooling weakens or error lights blink. That inspection fee clears to S$0 on confirmed repair or installation under 30-day repair terms.
- Multi-split homes with three or more indoor coils qualify for bulk rates. General cleaning runs S$25 per fan coil (14-day workmanship warranty), chemical washing S$60 (60-day), and overhauls S$115 (90-day).
- Pairing two indoor heads bills S$30 apiece for routine maintenance. Chemical washing rises to S$70 apiece, while full teardowns cost S$125 apiece.
- Standalone single-head calls carry fixed rates. General cleans run S$50, chemical washes run S$80, and full teardowns run S$150 to strip heavy drain biofilm.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Samsung · Wall-mounted
Coastal unit losing gas again: salt ate the pipe fitting
A corroded outdoor fitting thinned past the point where it can seal

Mitsubishi Electric · Wall-mounted
Warm air with normal gas pressure: fouled coil, not low gas
Grease-choked indoor evaporator coil and dust-packed blower wheel causing poor temperature drop while refrigerant pressure stayed full