On this page
Quick summary
Daikin RZFV100AVMG holds NEA 5-tick listing ELS-DAI-AC250110 until 6 November 2028 at 9.08 kW capacity, 5.56 weighted COP, and 3,568 kWh annual test draw. SP Group bills that yearly benchmark at S$1,112 against S$963 printed on the label.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Review RZFV100AVMG Efficiency and SP Group Annual Cost
Certified under NEA registration ELS-DAI-AC250110 through 6 November 2028, Daikin RZFV100AVMG reaches 5 ticks at 9.08 kW cooling capacity. Efficiency logs 4.77 full load, 6.09 part load, and 5.56 weighted COP.
Annual benchmark draw equals 3,568 kWh, shown as S$963 on the NEA energy sticker. Current GST-included charges of 31.16 cents for each kWh put yearly benchmark use at S$1,112, or S$93 monthly.
Full-load cooling draws around 1.90 kW (~59 cents hourly). Steady half-load modulation drops near 0.75 kW (~23 cents hourly) thanks to its high 6.09 part-load COP.
Compare RZFV100AVMG Specifications and Space Limits
Check certified Daikin RZFV100AVMG output alongside large residential hall and commercial floor criteria:
Scroll to see more columns
| Assessment item | RZFV100AVMG certified metric | Singapore site implication | Pre-purchase check |
|---|---|---|---|
| NEA registration | ELS-DAI-AC250110 (5 ticks) | Valid until 6 November 2028 | Verify certificate on label |
| Capacity and COP | 9.08 kW | 5.56 weighted COP | 4.77 full load; 6.09 part load | Fits large halls over 40 sqm |
| Annual electricity | 3,568 kWh per year | S$963 label vs S$1,112 SP Group | Roughly S$93 monthly benchmark |
| Power and placement | High-capacity outdoor chassis | Needs dedicated isolator capacity | Verify ledge space and amps |
Check Electrical Supply, Ledge Space, and Voucher Scope
Delivering 9.08 kW (roughly 31,000 BTU), RZFV100AVMG serves big condo living halls, landed dining zones, or commercial offices. Have an EMA licensed electrician inspect main breaker headroom and isolator amperage before delivery.
Verify physical ledge width and exhaust airflow clearance before ordering oversized outdoor condensers on HDB blocks. Eligible HDB flats apply S$400 Climate Vouchers through December 2027, whereas commercial offices explore GoBusiness Energy Efficiency Grants.
Oversized single splits placed into small bedrooms short-cycle rapidly and create cold drafts. Sizing floor space properly ensures quiet 6.09 part-load operation and steadier room humidity control.
Choose Servicing Schedules for High-Capacity RZFV100AVMG Splits
High airflow volumes across 9.08 kW coils quickly trap hall lint unless filters and pans stay clean:
- Arrange a S$30 site check ($80 on VRV setups) whenever supply air warms up. Approved repair or replacement jobs waive that visit charge under 30-day warranty.
- Regular quarterly cleaning bills S$50 for one high-capacity unit (14-day warranty). Servicing two units lowers rates to S$30 apiece, with multi-zone bookings of three-plus rooms billed S$25 each.
- Hall dust coatings lift cleanly via chemical washing at S$80 for a lone high-capacity unit (60-day cover). Twin setups total S$140 (S$70 per unit), while larger suites with three-plus heads run S$60 per blower.
- Stubborn pan biofilm needs dismantled teardown cleaning at S$150 per solo unit (90-day cover). Dual units cost S$125 each, or S$115 per unit across three-plus zones.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Daikin · Wall-mounted
Tripping a 20A breaker: weak capacitor, not compressor
Degraded outdoor run capacitor combined with a dust-choked condenser coil climbing amp draw past the 20A breaker limit after 15 minutes while the compressor remains sound

Daikin · Wall-mounted
Daikin J6 outdoor red LED: bad thermistor, not condenser
Open-circuit Daikin outdoor heat-exchanger thermistor halting multi-split cooling via outdoor safety protection while the inverter compressor stays healthy
Common Questions
Is Daikin RZFV100AVMG meant for an HDB bedroom or a large living hall?
How much electricity does Daikin RZFV100AVMG consume yearly under SP Group tariffs?
What electrical check is needed before installing a 9.08 kW Daikin RZFV100AVMG?
Can HDB flats fit a Daikin RZFV100AVMG condenser onto standard ledges?
Sources