Quick summary
Gree GWC-09SP/O holds 5 green ticks under listing ELS-GAS-AC250103 until 4 September 2028, rating 2.62 kW output and 5.74 weighted COP. Its 1,004 kWh test figure equals S$313 yearly at SP's 31.16c tariff, while eligible HDB homes claim S$400 voucher savings.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Check GWC-09SP/O Registered Output and Late 2026 Tariff Bill
Listing ELS-GAS-AC250103 stays valid until 4 September 2028 with 5 green ticks. Gree GWC-09SP/O rates 2.62 kW cooling, 5.06 full-load COP, 6.20 part-load COP, and 5.74 weighted COP.
Annual lab draw measures 1,004 kWh, printed as S$271 on the NEA energy tag. Multiplying 1,004 kWh by SP's 31.16c Q4 billing rate (GST included) totals S$313 yearly.
Five-tick HDB buyers also knock S$400 off hardware pricing via NEA's voucher scheme until late 2027. A standalone single-split chassis keeps any fault isolated to one room.
Compare GWC-09SP/O Efficiency Metrics and Room Fit
Check NEA test figures beside late 2026 running costs and bedroom sizing limits:
Scroll to see more columns
| GWC-09SP/O attribute | Verified NEA listing | SP Group Q4 2026 view | Bedroom deployment note |
|---|---|---|---|
| Certificate & expiry | ELS-GAS-AC250103 (5 ticks) | Valid to 4 September 2028 | HDB S$400 voucher grant eligible |
| Cooling capacity | 2.62 kW single split | 9,000 BTU nominal class | Suits 9 to 13 sq m bedrooms |
| Efficiency scores | 5.06 full / 6.20 part | 5.74 weighted COP | Economical overnight sleep modulation |
| Yearly test draw | 1,004 kWh annual figure | S$271 NEA / S$313 SP bill | At 31.16 cents/kWh incl. GST |
Match GWC-09SP/O to HDB Bedrooms and Condo Studies
Output at 2.62 kW suits common bedrooms, nurseries, and enclosed studies from 9 to 13 square metres. Sun-heated master suites past 15 square metres cool better with a 12,000 BTU model.
Adding one standalone outdoor condenser works best when the ledge keeps clear rear airflow. Check wall power point ratings and neat drain routing prior to purchase.
Proper pipe wall thickness and tight foam lagging keep slim wall trunking dry through wet monsoon months.
Schedule GWC-09SP/O Maintenance and Verify Installation
Clean evaporator fins protect part-load 6.20 COP efficiency across humid nights:
- Residential split fault visits run S$30, while VRV site inspections cost S$80. That visit charge drops off the bill whenever repair or install work proceeds (30-day warranty).
- One lone GWC-09SP/O blower bills S$50 for general washes (14-day warranty). Chemical coil cleans run S$80 with 60-day protection, while overhauls cost S$150 (90-day cover).
- Combining two home blowers sets general care at S$30 per blower. Two-unit chemical washes drop to S$70 per head, and two-unit overhauls run S$125 per head.
- Three-plus rooms lower fees further: general visits cost S$25 per coil, chemical treatment runs S$60 per coil, and dismantled overhauls sit at S$115 per coil.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Gree · Wall-mounted
Gree F0 on a rusted condenser: refrigerant shortage
R32 refrigerant shortage triggering Gree F0 protection from corroded evaporator return bends

Mitsubishi Electric · Wall-mounted
Warm air with normal gas pressure: fouled coil, not low gas
Grease-choked indoor evaporator coil and dust-packed blower wheel causing poor temperature drop while refrigerant pressure stayed full
Common Questions
How much electricity does Gree GWC-09SP/O consume per year in Singapore?
Which Singapore room size matches Gree GWC-09SP/O 2.62 kW capacity best?
Can HDB owners use Climate Vouchers on Gree GWC-09SP/O?
What warranty covers Gree GWC-09SP/O general and chemical servicing?
Sources