On this page
Quick summary
Toshiba RAS-4M41U2ACVG-SG holds NEA 5-tick certificate MELS-CAR-AC210021 at 6.64 kW cooling capacity and 6.15 weighted COP. Its 2,377 kWh test consumption costs S$741 yearly under late-2026 electricity tariffs. HDB owners can also apply S$400 Climate Vouchers on eligible upgrades.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Check RAS-4M41U2ACVG-SG Efficiency and SP Group Bill Math
Toshiba RAS-4M41U2ACVG-SG holds NEA certificate MELS-CAR-AC210021 through 23 March 2027. The 5-tick multi-split reaches 6.64 kW cooling output. Tested efficiency logs 5.44 full-load COP, 6.62 part-load COP, and 6.15 weighted COP.
Official NEA testing reports 2,377 kWh yearly electricity draw, printed as S$642 on the label. Applying late-2026 GST-inclusive pricing of 31.16 cents/kWh makes that benchmark S$741 yearly.
Running one 9,000 BTU bedroom overnight at 25°C favours the 6.62 part-load rating. Eligible HDB flats get S$400 Climate Vouchers before 2028, though buyers should confirm certificate renewal dates first.
Compare RAS-4M41U2ACVG-SG Ratings, Flat Fit, and Maintenance Tiers
Match this Toshiba system against room heat load and published maintenance fees. Accurate capacity matching avoids wasted compressor cycling and keeps warranty coverage valid:
Scroll to see more columns
| Specification item | RAS-4M41U2ACVG-SG metric | Singapore benchmark | Owner planning note |
|---|---|---|---|
| NEA 5-tick listing | MELS-CAR-AC210021 | 6.64 kW | 6.15 weighted COP | Expires 23 March 2027 |
| Annual energy cost | 2,377 kWh test benchmark | S$642 NEA | S$741 Q4 tariff | Based on 31.16c/kWh rate |
| Recommended flat type | 3-room or compact 4-room HDB | Up to three indoor heads | Avoid oversized hall loads |
| Survey and repair check | System layout evaluation | S$30 check (waived on work) | Carries 30-day repair cover |
Size Indoor Heads and HDB Condenser Clearance Properly
Three 9,000 BTU bedrooms pair well with a 6.64 kW condenser when daytime hall use stays separate. Running two bedrooms alongside a sunny living zone pushes full-load draw toward 5.44 COP. Staggered schedules keep night power usage low.
Keep HDB condenser ledges unobstructed so hot exhaust never loops back into outdoor fins. Specify thick 22 SWG copper pipes and half-inch closed-cell insulation during installs. Proper lagging stops hidden condensation leaks along ceiling trunking. Checking flare joints before handover prevents slow refrigerant losses.
Plan Toshiba Servicing Intervals and Voucher Timing
Clean evaporator coils preserve Toshiba's 6.15 weighted COP across humid Singapore months. Book servicing together across rooms to cut per-unit bills:
- One indoor unit pays S$50 for general cleaning, S$80 for chemical wash, or S$150 for dismantled chemical overhaul.
- Servicing two indoor units reduces per-head fees to S$30 general, S$70 chemical, and S$125 overhaul.
- Booking three or more indoor blowers lowers per-unit prices to S$25 general (14-day warranty), S$60 chemical (60-day warranty), and S$115 overhaul (90-day warranty).
- Request an initial S$30 site survey before replacement. Snowflake waives that visit fee once installation or repair proceeds.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Samsung · Wall-mounted
Coastal unit losing gas again: salt ate the pipe fitting
A corroded outdoor fitting thinned past the point where it can seal

Daikin · Wall-mounted
Daikin J6 outdoor red LED: bad thermistor, not condenser
Open-circuit Daikin outdoor heat-exchanger thermistor halting multi-split cooling via outdoor safety protection while the inverter compressor stays healthy
Common Questions
How much does Toshiba RAS-4M41U2ACVG-SG cost to run per year in Singapore?
Which Singapore flat sizes suit Toshiba RAS-4M41U2ACVG-SG best?
Can HDB owners redeem Climate Vouchers on Toshiba RAS-4M41U2ACVG-SG?
How often should Toshiba RAS-4M41U2ACVG-SG indoor coils be serviced?