Midea MABOD-09E Single Split kWh and Ownership Guide

Midea MABOD-09E delivers 2.83 kW cooling alongside 5.74 weighted COP and 1,104 kWh yearly lab usage on listing ELS-MSP-AC260006. Check local electricity bills, room sizing, and servicing rates below.

On this page

Quick summary

Midea MABOD-09E carries NEA 5-tick listing ELS-MSP-AC260006 through 14 January 2029 at 2.83 kW capacity, 5.74 weighted COP, and 1,104 kWh yearly test draw. Household billing at 31.16 cents/kWh (inclusive of GST) estimates S$344 annually across Singapore bedrooms.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Review MABOD-09E Efficiency Scores and SP Group Bills

Registered on certificate ELS-MSP-AC260006 until 14 January 2029, Midea MABOD-09E earns 5 ticks at 2.83 kW capacity. Full-load efficiency reads 4.63 COP while part-load output climbs to 6.48 COP, reaching 5.74 weighted COP.

Standard NEA testing logs 1,104 kWh annually, shown as S$298 on yellow energy stickers. Including GST, household power pricing of 31.16 cents/kWh makes that yearly benchmark cost S$344.

Single-split units suit daytime work-from-home studies cleanly. One compact compressor cools one room without running an oversized System 3 outdoor box.

Compare MABOD-09E Lab Figures and Bedroom Fit

See how Midea MABOD-09E figures translate to Singapore HDB and condo bedroom conditions:

Scroll to see more columns

Compare MABOD-09E lab figures and bedroom fit summary table
Model specificationVerified NEA figureSP Group bill viewSingapore room guidance
Cooling output2.83 kW (5 ticks)Around 9,650 BTU classFits shaded bedrooms up to 13 sq m
COP performance4.63 full and 6.48 part5.74 weighted COPSaves power on steady night cycles
Annual test energy1,104 kWh yearlyS$344 at 31.16 cents/kWhS$298 printed on older label rate
COR and grant statusELS-MSP-AC260006Expires 14 Jan 2029HDB S$400 voucher eligible to late 2027

Check HDB Ledge Limits and Dedicated Piping Rules

Fitting a standalone MABOD-09E beside an active System 3 condenser requires careful ledge measurement upfront. Many BTO aircon ledges lack side exhaust room for two separate outdoor housings.

Insist on 22 SWG copper piping wrapped in Shield CX half-inch insulation. Verify circuit load headroom with an EMA Licensed Electrical Worker before install day. Qualifying HDB households offset upgrades using S$400 vouchers before late 2027.

Choose Your MABOD-09E Servicing and Upgrade Timing

Clean evaporator fins preserve that 6.48 part-load efficiency across humid Singapore nights:

  • Quarterly general washes protect quiet airflow with 14-day workmanship cover. Solo splits pay S$50, twin units pay S$30 per head, while bookings of three or more pay S$25 per head.
  • Sticky bedroom grease requires chemical servicing holding a 60-day guarantee. Chemical washes run S$60 per FCU on three-plus rooms, S$70 per FCU in pairs, and S$80 for one room.
  • Sludge-blocked pans clear through dismantled overhauls holding a 90-day guarantee. Lone rooms charge S$150, dual rooms charge S$125 apiece, and three-plus rooms charge S$115 apiece.
  • Sudden warm air or rattles start with a S$30 fault visit (S$80 VRV) backed by 30-day repair coverage. Proceeding with repair or installation waives that visit fee.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

What room size suits a 2.83 kW Midea MABOD-09E single split in Singapore?
Rated at 2.83 kW, Midea MABOD-09E cools standard HDB common bedrooms, helper quarters, or shaded study rooms around 9 to 13 square metres comfortably. Hot west-facing master rooms or studios cope better with the larger 3.45 kW MABOD-12E.
Why does SP Group electricity billing reach S$344 instead of Midea MABOD-09E's S$298 label?
Yellow NEA labels price power at a fixed 27-cent historical benchmark, producing S$298 for 1,104 kWh. Using late-2026 GST-included utility billing at 31.16 cents/kWh raises that yearly benchmark to S$344.
Can HDB owners apply S$400 Climate Vouchers toward Midea MABOD-09E?
Listed under NEA registration ELS-MSP-AC260006 with a full 5-tick rating, Midea MABOD-09E meets Climate Voucher criteria at participating stores. Eligible HDB flat households can redeem their S$400 grant before December 2027 ends.
Does adding a Midea MABOD-09E outdoor unit fit an HDB ledge beside a System 3?
Most newer BTO ledges hold one multi-split condenser cleanly, leaving little airflow room for a second box beside it. Checking exact ledge widths, HDB Form AC-02 rules, and isolator capacity prevents restricted hot exhaust.

Sources

Sources checked 27 Nov 2026

  1. NEA Registered Goods PortalNational Environment Agency (NEA) · Checked 27 Nov 2026
  2. SP Group Electricity Tariff InformationSP Group · Checked 27 Nov 2026
  3. NEA Climate Vouchers Air-Conditioners GuideNational Environment Agency (NEA) · Checked 27 Nov 2026