On this page
Quick summary
Fujitsu AOAG09CMTA holds NEA 5-tick listing MELS-WIN-AC220063 until 11 July 2028 at 2.87 kW capacity, 6.28 weighted COP, and 993 kWh annual test draw. Under Singapore's 31.16-cent regulated domestic rate, yearly benchmark electricity runs S$309.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Verify AOAG09CMTA NEA Figures and SP Group Electricity Bills
Registered under MELS-WIN-AC220063 until 11 July 2028, Fujitsu AOAG09CMTA delivers 2.87 kW cooling with 5 green ticks. Efficiency reaches 5.44 full-load COP, 6.84 part-load COP, and 6.28 weighted COP. Low-speed inverter operation saves energy steadily throughout eight-hour sleep cycles.
Annual NEA consumption measures 993 kWh, marked at S$268 on the green sticker. SP Group collects 31.16 cents (inclusive of GST) for every kWh consumed, making 993 kWh worth S$309 annually (near S$25.75 monthly). Five-tick single splits also qualify for S$400 HDB household vouchers until 31 December 2027 through registered climate merchants.
Compare AOAG09CMTA Bedroom Sizing and Part-Load Savings
Check Fujitsu AOAG09CMTA benchmark metrics and room matching before confirming your single-split quotation. Compact bedrooms benefit most because moderate capacity avoids harsh compressor cycling. Cool rainy evenings drop overnight compressor speeds even lower.
Scroll to see more columns
| Evaluation metric | Fujitsu AOAG09CMTA data | Test rating basis | Singapore bedroom note |
|---|---|---|---|
| NEA MELS status | MELS-WIN-AC220063 (5 ticks) | Valid through 11 Jul 2028 | Confirm indoor-outdoor pairing |
| Cooling & efficiency | 2.87 kW output | 5.44 full; 6.84 part COP | 6.28 weighted COP savings |
| Annual test energy | 993 kWh yearly benchmark | S$268 NEA label estimate | S$309 yearly on SP 31.16c |
| Room & voucher match | Common bedroom or study | S$400 Climate Voucher fit | Low idle draw at 25 degrees |
Keep Single-Split Bedrooms Dry and Efficient Overnight
At 2.87 kW output, Fujitsu AOAG09CMTA fits standard HDB common bedrooms, compact studies, and helper rooms without oversizing. Its 6.84 part-load COP excels once walls cool down and inverter frequency throttles low overnight. Steady humidity removal keeps bedding comfortable without clammy air. Keep bedroom doors shut and window gaps sealed to preserve efficiency.
Gentle low-speed airflow still carries humidity into condensate trays, feeding biofilm whenever mesh screens gather dust. Rinse removable indoor filters from floor level fortnightly and leave exterior ledge work strictly to certified technicians. Clear drainage keeps bedroom walls dry without overnight drip stains.
Plan Fujitsu AOAG09CMTA Maintenance and Fault Diagnostics
Preserve that 993 kWh benchmark across tropical humidity with predictable servicing intervals:
- Call in a technician for a S$30 inspection whenever cooling weakens; fees waive on confirmed repair or install jobs with 30-day warranty terms.
- Basic seasonal servicing runs S$50 (single FCU), S$30/FCU (dual FCUs), and S$25/FCU (three-plus FCUs) carrying 14 days of workmanship assurance.
- Alkaline coil washes eliminate musty smells at S$80 (1 blower), S$70 per blower (2 blowers), or S$60 per blower (3+ blowers) with a 60-day warranty.
- Full drain-pan teardowns clear persistent drips: S$150 covers one room, S$125/room covers two, and S$115/room covers three or more rooms for 90 days.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Fujitsu · Cassette
Office cassette dripping at louver: sweating from fouled coil
Surface condensation on the supply louver driven by restricted airflow across one fouled coil face

Daikin · Wall-mounted
Water stain down the wall: blocked rear drain trough
Biofilm jelly choking the hidden rear auxiliary drain trough behind the evaporator coil, spilling condensate down the plastered wall while the main trunking pipe stayed intact
Common Questions
Which Singapore rooms match the 2.87 kW Fujitsu AOAG09CMTA best?
How much does running Fujitsu AOAG09CMTA cost on SP Group tariffs?
Why is the Fujitsu AOAG09CMTA part-load COP 6.84 higher than its 5.44 full-load COP?
Do single-split bedrooms like Fujitsu AOAG09CMTA still need chemical servicing?
Sources
Sources checked 27 Nov 2026