Fujitsu AOAG12CMTA Single Split kWh and Cost Guide

Certified under MELS-WIN-AC220061, Fujitsu AOAG12CMTA delivers 3.59 kW cooling at 5.9 weighted COP and 1,326 kWh yearly draw. Check SP Group costs, master bedroom fit, and upkeep below.

On this page

Quick summary

Fujitsu AOAG12CMTA holds active NEA 5-tick listing MELS-WIN-AC220061 until 11 July 2028 at 3.59 kW output, 5.9 weighted COP, and 1,326 kWh annual draw. Paying 31.16 cents for each kWh brings annual benchmark power to S$413, while HDB owners offset bills with S$400 vouchers.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Check AOAG12CMTA NEA Figures and Late 2026 Electricity Cost

Listed under certificate MELS-WIN-AC220061 until 11 July 2028, Fujitsu AOAG12CMTA carries 5 green ticks at 3.59 kW capacity. Test COP values reach 5.04 full load, 6.48 part load, and 5.9 weighted.

Printed stickers list 1,326 kWh yearly draw and a S$358 label cost. Multiplying 1,326 kWh by Q4 2026's 31.16-cent regulated tariff yields S$413 per year, or S$34.40 per month. HDB flats also offset costs using S$400 Climate Vouchers before 2028.

Compare AOAG12CMTA Specifications Against Singapore Flat Spaces

Check verified NEA registration numbers and piping specs before booking single-split installs for warm rooms. Reviewing label metrics beside room size prevents oversizing:

Scroll to see more columns

Compare AOAG12CMTA specifications against Singapore flat spaces summary table
Specification itemFujitsu AOAG12CMTA figureBenchmark basisPractical flat note
NEA MELS certificateMELS-WIN-AC220061 (5 ticks)Expires 11 Jul 2028Unlocks S$400 HDB voucher
Cooling and COP3.59 kW (~12,250 BTU)5.04 full / 6.48 part COP5.9 weighted efficiency
Annual label draw1,326 kWh test yearlyS$358 sticker estimateS$413 yearly on SP tariff
Best room application14 to 20 sqm room22 SWG copper + 0.5-in foamHandles west afternoon sun

Match 3.59 kW Cooling Cleanly to Warm Bedrooms and Studies

Supplying 3.59 kW (~12,250 BTU), Fujitsu AOAG12CMTA sits neatly between 9,000 BTU common-room units and 18,000 BTU hall blowers. West-facing HDB master suites and warm study rooms benefit from that extra pull-down power.

Once night temperatures drop, inverter frequency settles near its 6.48 part-load curve. Pair new runs with 22 SWG copper, thick 0.5-inch closed-cell lagging, and 500-micron vacuuming to protect R32 oil. Keeping doors closed and rinsing dust screens fortnightly stops coils from icing and keeps night draw lean.

Schedule Fujitsu AOAG12CMTA Surveys and Routine Servicing

Clean blower wheels and free-flowing drains keep bedroom power bills steady across humid Singapore nights:

  • Site checks charge S$30 on splits, whereas VRV equipment bills S$80. Confirmed installs waive this survey fee, and repairs hold 30-day coverage.
  • General washes run S$50 for a solo room, S$30/unit for two, and S$25/unit for three or more. Every clean includes 14-day cover.
  • Musty evaporator fins clear via chemical washing. Cleaning one unit runs S$80, two units total S$140 (S$70/unit), and three-plus bill S$60/unit with 60-day assurance.
  • Deep chemical teardowns resolve leaks at S$150 for 1 blower. Pairs charge S$125 each, and 3+ blowers charge S$115 each (90-day cover).

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

How much does Fujitsu AOAG12CMTA cost to run yearly on SP Group rates?
At SP Group's current 31.16-cent rate (GST included), 1,326 kWh of yearly test power works out to S$413 annually, or roughly S$34.40 each month. Actual household spending moves up or down with thermostat settings and nightly run time.
Should a common HDB bedroom pick Fujitsu AOAG12CMTA over a 9,000 BTU model?
Compact 9 to 12 sqm common HDB bedrooms generally run quieter on smaller 2.6 to 2.9 kW splits, whereas 3.59 kW Fujitsu AOAG12CMTA suits 14 to 20 sqm master bedrooms, sunny west-facing rooms, or enclosed home offices.
Can HDB homeowners claim S$400 Climate Vouchers on Fujitsu AOAG12CMTA?
Qualifying HDB households receive S$400 in green Climate Vouchers usable on 5-tick residential aircons like Fujitsu AOAG12CMTA (MELS-WIN-AC220061) before year-end 2027. Always confirm dealer participation and remaining voucher balance before paying deposits.
What servicing routine protects the 6.48 part-load COP on Fujitsu AOAG12CMTA?
Quarterly general servicing keeps indoor squirrel-cage wheels free of lint so evaporator pressure stays balanced during low-speed sleep hours. Adding annual chemical coil flushing clears biofilm buildup common in humid Singapore bedrooms.

Sources

Sources checked 27 Nov 2026

  1. NEA Registered Goods PortalNational Environment Agency (NEA) · Checked 27 Nov 2026
  2. SP Group Electricity Tariff InformationSP Group · Checked 27 Nov 2026
  3. NEA Climate Friendly Households AirconsNational Environment Agency (NEA) · Checked 27 Nov 2026