Gree GWC-12Charmo/O Single-Split 5-Tick Guide

Gree GWC-12Charmo/O provides 3.48 kW single-split cooling at 5.83 weighted COP and 1,302 kWh annually under ELS-GAS-AC250032. Review late 2026 power bills, master room fit, and servicing fees below.

On this page

Quick summary

Gree GWC-12Charmo/O holds 5-tick NEA approval under ELS-GAS-AC250032 until 13 March 2028, rating 3.48 kW cooling and 5.83 weighted COP. Its 1,302 kWh benchmark costs S$406 yearly at SP's Q4 rate, while HDB homes trim S$400 off with Climate Vouchers.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Review GWC-12Charmo/O Label Data and Late 2026 SP Group Cost

NEA registration ELS-GAS-AC250032 lists Gree GWC-12Charmo/O at 5 green ticks until 13 March 2028. Rated cooling reaches 3.48 kW with 4.99 full-load COP and 6.39 part-load COP.

Weighted COP hits 5.83, keeping overnight running power low once rooms cool to 25 degrees. Lab tests log 1,302 kWh yearly, shown as S$352 on the energy tag.

Singapore's late-2026 31.16-cent GST-included rate puts 1,302 kWh at S$406 yearly. Five-tick HDB buyers also claim S$400 voucher support until late 2027.

Compare GWC-12Charmo/O Rated Metrics and HDB Placement

Compare NEA test benchmarks beside late 2026 utility charges and Singapore bedroom suitability:

Scroll to see more columns

Compare GWC-12Charmo/O rated metrics and HDB placement summary table
Specification lineGWC-12Charmo/O listingLate 2026 bill figureSingapore room suitability
NEA registrationELS-GAS-AC250032 (5 ticks)Expires 13 March 2028Eligible for S$400 HDB Climate Voucher
Cooling capacity3.48 kW single split12,000 BTU output classSuits 15 to 21 sq m master rooms
COP breakdown4.99 full / 6.39 part5.83 weighted efficiencyStrong part-load turndown overnight
Annual electricity1,302 kWh benchmarkS$352 NEA / S$406 SP billCalculated at 31.16c/kWh GST-included

Fit GWC-12Charmo/O to Larger Bedrooms and Warm Study Rooms

With 3.48 kW cooling, GWC-12Charmo/O suits sunny HDB master suites, wardrobe rooms, and warm 15 to 21 square metre dens. Smaller 9 to 12 square metre rooms cool better on a 2.6 kW unit.

Check rear condenser ledge space and power switch capacity before adding a single-split set. Open rear airflow protects compressor health on hot afternoons.

Sealed drain elbows and sloped PVC runs stop slimy water overflow marks on newly painted master walls.

Book GWC-12Charmo/O Installation Check and Care Cadence

Clean evaporator coils preserve that high 6.39 part-load COP without forcing noisy fan speeds:

  • Commercial VRV checks run S$80, whereas standard split surveys start at S$30. Any check charge waives once installation or repair starts (30-day warranty).
  • A lone GWC-12Charmo/O unit pays S$50 for general servicing under 14-day terms. Single-head chemical cleaning costs S$80 (60-day cover), and a teardown overhaul costs S$150 (90-day cover).
  • Adding a second room brings general fees to S$30 per head. Chemical cleaning drops to S$70 per unit, while two-unit overhauls cost S$125 per unit.
  • Bookings covering three or more blowers unlock S$25 general washes per unit. Chemical cleans drop to S$60 per blower, and overhauls drop to S$115 per blower.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Why is Gree GWC-12Charmo/O tagged S$352 by NEA yet S$406 under SP Group?
NEA stamps S$352 using an older fixed assumption on the sticker for 1,302 kWh yearly use. Applying SP Group's 31.16c Q4 2026 GST-included tariff values those same 1,302 kWh at S$406.
How does Gree GWC-12Charmo/O compare with GWC-12SP/O on efficiency?
Gree GWC-12Charmo/O scores 5.83 weighted COP and 6.39 part-load COP across 3.48 kW output, using 1,302 kWh yearly. Those certified figures edge out the 5.59 weighted COP and 1,332 kWh draw listed for GWC-12SP/O.
Does Gree GWC-12Charmo/O work with Singapore's HDB Climate Voucher grant?
Verified 5-tick models accept Singapore's S$400 Climate Voucher grant for HDB flats until end-2027. Certificate ELS-GAS-AC250032 holds active 5-tick registration through 13 March 2028 at participating local dealers.
When should a Gree GWC-12Charmo/O owner pick chemical servicing over general cleaning?
Quarterly general cleaning clears dry dust off mesh filters and trays for S$50 on one unit. Sticky coil slime, musty smells, or weak airflow call for a S$80 chemical wash or S$150 full overhaul.

Sources

Sources checked 27 Nov 2026

  1. NEA Registered Goods PortalNational Environment Agency (NEA) · Checked 27 Nov 2026
  2. SP Group Electricity Tariff InformationSP Group · Checked 27 Nov 2026
  3. NEA Climate Vouchers Aircon EligibilityNational Environment Agency (NEA) · Checked 27 Nov 2026