Quick summary
Toshiba RAS-4M41P2ACVG-SG carries NEA 5-tick certificate ELS-CAR-AC250061 at 6.6 kW capacity, 6.1 weighted COP, and 2,400 kWh yearly test use. Applying SP Group's late-2026 electricity rate brings the benchmark bill to S$748 annually, suiting larger multi-room HDB and condominium households.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Break Down RAS-4M41P2ACVG-SG COP and Electricity Costs
Certificate ELS-CAR-AC250061 confirms 5-tick status for Toshiba RAS-4M41P2ACVG-SG until 10 April 2028. Rated cooling output reaches 6.6 kW alongside 5.48 full-load COP, 6.51 part-load COP, and 6.1 weighted COP.
Annual lab usage equals 2,400 kWh, printed as S$648 on the NEA energy label. Priced under SP Group's 0.3116 S$/kWh late-2026 tariff (inclusive of GST), that 2,400 kWh benchmark totals S$748 annually.
Strong 6.51 part-load COP lowers night compressor draw when cooling bedrooms at 25 degrees. Qualifying HDB upgrades can also claim HDB Climate Vouchers worth S$400 up to end-2027.
Compare RAS-4M41P2ACVG-SG Ratings Against Household Demand
Evaluate certified ELS-CAR-AC250061 performance benchmarks alongside practical Singapore home demand below:
Scroll to see more columns
| Evaluation metric | RAS-4M41P2ACVG-SG benchmark | Operational significance | Ownership note |
|---|---|---|---|
| NEA MELS status | ELS-CAR-AC250061 (5 ticks) | Valid through 10 April 2028 | Eligible HDB homes check voucher rules |
| Efficiency curve | 5.48 full / 6.51 part / 6.1 weighted | Minimal energy waste during light night cooling | Beats standard 3-tick compressors noticeably |
| Yearly energy cost | 2,400 kWh test figure | S$648 label estimate vs S$748 SP rate | Afternoon living-hall hours shift actual spend |
| Multi-split output | 6.6 kW cooling capacity | Handles bedrooms nightly plus staggered day use | Check diversity before maxing four heads |
| Multi-unit maintenance | Three-plus coils qualify for bulk tier | S$25 general | S$60 chemical | S$115 overhaul | Waived S$30 check when work proceeds |
Plan Room Diversity and HDB Power Limits Cleanly
While 6.6 kW cools three sleeping rooms smoothly after sunset, opening four indoor blowers simultaneously during fierce afternoon glare splits total capacity thinly. Shading west-facing glass keeps indoor blowers within efficient part-load range.
Older HDB estates enforce strict electrical loading caps, exterior ledge clearances, and bathroom floor-trap drain routing. Verify existing isolator amperage, bracket hardware, and concealed copper condition before commissioning a 6.6 kW multi-split condenser.
Swapping mismatched older piping prevents oil return problems on inverter compressors. Always check outdoor exhaust louvre clearance so hot discharge air never bounces back across the condenser coil.
Choose a Servicing Schedule and Pre-Install Inspection
Consistent preventive care keeps evaporator fins clean so Toshiba's inverter stays near its 6.51 part-load sweet spot, while gentle fortnightly filter vacuuming preserves indoor airflow:
- Arrange a S$30 pre-installation inspection first (or S$80 on VRV properties). Snowflake waives that survey charge when repair or installation goes forward, with 30-day repair coverage.
- Routine general cleaning covers three or more indoor coils at S$25 per coil, two coils at S$30 per coil, and one coil at S$50, carrying 14-day workmanship protection.
- Clear stubborn biofilm and foul drain trays via chemical cleaning priced at S$60 per room across three-plus units, S$70 per unit on pairs, or S$80 on a lone unit (60-day cover).
- Heavy coil choking or tenancy turnarounds warrant dismantled chemical overhauls at S$115 per unit across three-plus rooms, S$125 each for pairs, or S$150 solo (90-day cover).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Daikin · Wall-mounted
Tripping a 20A breaker: weak capacitor, not compressor
Degraded outdoor run capacitor combined with a dust-choked condenser coil climbing amp draw past the 20A breaker limit after 15 minutes while the compressor remains sound

Daikin · Wall-mounted
Daikin J6 outdoor red LED: bad thermistor, not condenser
Open-circuit Daikin outdoor heat-exchanger thermistor halting multi-split cooling via outdoor safety protection while the inverter compressor stays healthy
Common Questions
How efficient is Toshiba RAS-4M41P2ACVG-SG compared with smaller multi-split units?
Why does SP Group cost S$748 yearly when the NEA sticker prints S$648?
Can Toshiba RAS-4M41P2ACVG-SG cool four rooms simultaneously during hot Singapore afternoons?
What flat servicing rates apply to a Toshiba RAS-4M41P2ACVG-SG multi-room installation?