Gree 5.39 kW 5-Tick Multi Split kWh and Ownership Guide

GREE GWCD(18)NK6AO pairs 5.39 kW multi-split capacity with 5.89 weighted COP under NEA listing MELS-SGR-AC220015. Review verified SP Group electricity bills, HDB bedroom limits, and upkeep schedules below.

On this page

Quick summary

GREE GWCD(18)NK6AO holds NEA 5-tick certificate MELS-SGR-AC220015 until 25 November 2027, offering 5.39 kW cooling at 5.89 weighted COP and 2,026 kWh yearly draw. That equals S$631 yearly on Q4 2026 SP Group billing (31.16 cents/kWh), fitting compact HDB flats.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Verify Gree 5.39 kW NEA Ratings and Late 2026 Electricity Math

Listed under NEA certificate MELS-SGR-AC220015 until 25 November 2027, GREE GWCD(18)NK6AO earns 5 ticks in the Multi Split class. Official testing records 5.39 kW capacity, 4.97 full-load COP, 6.50 part-load COP, and 5.89 weighted COP.

Annual lab usage equals 2,026 kWh, printed as S$547 on older tick labels. Applying SP Group's regulated 31.16 cents per kWh rate puts that same benchmark at S$631 annually. HDB households also deduct S$400 via official Climate Vouchers before 2028.

Compare Gree 5.39 kW Benchmark Figures and Singapore Flat Fit

Review official NEA efficiency numbers beside late 2026 tariff math and room pairing limits. Notice how part-load COP beats full-load draw:

Scroll to see more columns

Compare Gree 5.39 kW benchmark figures and Singapore flat fit summary table
Specification metricVerified NEA figureSingapore tariff impactFlat sizing note
NEA MELS certificateMELS-SGR-AC220015 (5 ticks)Eligible for S$400 HDB vouchersValid until 25 November 2027
Cooling capacity class5.39 kW Multi SplitRoughly 18,390 BTU/h ceilingSuits two bedrooms at once
Full / part / weighted COP4.97 / 6.50 / 5.89 COPPeak savings at overnight part loadAvoid full-load hall + room overlap
Annual test energy draw2,026 kWh per yearS$631/yr (vs S$547 NEA label)Clean filters keep part load efficient

Size Gree 5.39 kW Room Pairings for HDB and Compact Condos

Total cooling of 5.39 kW handles two typical 9,000 BTU bedrooms cleanly overnight. Operating within that two-room band holds compressor efficiency near its 6.50 part-load rating. Adding a study unit works best when daytime and night schedules stay separate.

Running three warm bedrooms simultaneously drives output down toward 4.97 full-load COP and slows cooling. Confirm pipe lengths and power points against HDB guidelines before purchase.

Choose Installation Survey Steps and Ongoing Upkeep Intervals

Protect the 5.89 weighted COP across humid Singapore months using planned inspections and coil care:

  • Validate 5.39 kW flat fit via a S$30 home assessment (S$80 on VRV properties). Snowflake credits that check fee completely when installation proceeds.
  • Keep indoor airflow free through quarterly upkeep. Cleaning one room costs S$50, twin rooms pay S$30 per blower, and three-unit homes pay S$25 apiece under 14-day terms.
  • Dissolve greasy fin buildup via chemical servicing: S$80 for a lone FCU, S$70 per FCU on twin jobs, or S$60 per FCU on triple-unit visits (60-day cover).
  • Stubborn drain slime calls for full strip-down overhauls. Expect S$150 single, S$125 per coil on twin sets, or S$115 per coil on triple-unit visits carrying 90-day workmanship cover.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Why is the SP Group annual cost higher than the S$547 figure on the GREE NEA label?
NEA labels calculate S$547 using a fixed reference rate of 27 cents per kWh. Applying SP Group's late 2026 GST-inclusive household tariff of 31.16 cents per kWh to the same 2,026 kWh benchmark produces S$631 yearly.
Can GREE GWCD(18)NK6AO run three bedrooms simultaneously in a larger HDB flat?
Operating three warm rooms together stretches a 5.39 kW outdoor unit near full load, cutting cooling speed. GWCD(18)NK6AO performs best powering two sleep bedrooms nightly or staggering study and living room hours.
Can HDB buyers redeem S$400 Climate Vouchers for GREE GWCD(18)NK6AO?
Eligible Singapore HDB households can claim S$400 Climate Vouchers through December 2027 on verified 5-tick models like MELS-SGR-AC220015, provided purchases happen through participating retailers under current HDB voucher rules.
How does skipped filter cleaning affect the 5.89 weighted COP of GWCD(18)NK6AO?
Matted indoor mesh filters starve coil airflow, forcing the inverter compressor to run longer at lower suction pressure and eroding real-world efficiency below its 6.50 part-load and 5.89 weighted COP ratings.