On this page
Quick summary
Hisense AMW100TERJ carries NEA 5-tick certificate ELS-HES-AC250020 through 19 February 2028, rating 5.65 kW cooling output, 5.82 weighted COP, and 2,114 kWh annual energy draw. Priced using SP Group's 31.16-cent GST-inclusive tariff, benchmark annual electricity runs S$659, qualifying eligible HDB homes for S$400 Climate Vouchers.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Verify Hisense AMW100TERJ Efficiency and SP Group Costs
Registered under NEA certificate ELS-HES-AC250020 until 19 February 2028, Hisense AMW100TERJ earns 5 energy ticks. Rated cooling reaches 5.65 kW. Official tests record 5.37 full-load COP, 6.12 part-load COP, and 5.82 weighted COP. High part-load efficiency matters most because Singapore HDB households sleep under reduced night compressor load.
Annual benchmark draw stands at 2,114 kWh, printed as S$571 on legacy NEA labels. Applying SP Group's Q4 2026 billing tier (31.16 cents each kWh, GST added), that same benchmark equals S$659 annually, averaging roughly S$55 monthly.
Compare AMW100TERJ Specifications and Ownership Metrics
Match NEA registration metrics directly against Singapore utility tariffs and flat upkeep allowances below.
Scroll to see more columns
| Ownership dimension | Verified Hisense data | Singapore tariff or rule | Practical HDB note |
|---|---|---|---|
| NEA MELS registration | ELS-HES-AC250020 (5 ticks) | Expires 19 February 2028 | Eligible for S$400 Climate Vouchers |
| Output & COP ratings | 5.65 kW | 5.82 weighted COP | 5.37 full load; 6.12 part load | Peaks when cooling 1–2 bedrooms nightly |
| Annual test energy spend | 2,114 kWh/yr (S$571 NEA label) | S$659/yr using 31.16c/kWh SP rate | Real bills track room temperature settings |
| Upkeep & survey fees | S$30 check waived on install/fix | S$25–S$50 clean; S$60–S$80 wash | Dismantled overhauls run S$115–S$150 |
Match 5.65 kW Capacity to HDB and Condo Rooms
Capacity of 5.65 kW equals roughly 19,280 BTU/hr total outdoor output. That sizing suits 2-room Flexi or 3-room HDB layouts cleanly. Running two bedrooms overnight keeps the inverter near its efficient 6.12 part-load COP peak.
Trying to cool three sunny bedrooms plus an open hall stretches 5.65 kW past comfortable limits. Check HDB Climate Voucher eligibility—worth S$400 on qualifying 5-tick models until December 2027. Specify thick copper walls plus closed-cell insulation during piping runs so condensation never forms inside trunking.
Also verify your existing HDB electrical isolator rating before replacement day. Clean flare torques and dry nitrogen flushing during installation preserve compressor oil purity from day one.
Plan Hisense Installation Checks and Servicing Cadence
Preserve your 5.82 weighted COP efficiency and avoid water leaks with predictable maintenance milestones:
- Confirm bedroom routing before ordering via an S$30 flat inspection—credited back when installing (VRV projects require S$80; repairs include 30 days warranty).
- Pair monthly filter rinses with flat multi-split packages: three indoor blowers qualify for S$25 general care (14-day warranty), S$60 chemical washes (60-day warranty), or S$115 coil overhauls (90-day warranty).
- One-unit or two-unit configurations pay S$50 and S$30 (general), S$80 and S$70 (chemical), or S$150 and S$125 (overhaul) per blower.
- Inspect outdoor ledge drainage and copper insulation cladding annually so afternoon tropical sun never cracks pipe lagging.
- Rinse washable indoor dust filters monthly to maintain smooth coil airflow across every bedroom.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Samsung · Wall-mounted
Coastal unit losing gas again: salt ate the pipe fitting
A corroded outdoor fitting thinned past the point where it can seal

Daikin · Cassette
Cassette not cooling: stuck gas-flow valve, not compressor
A flow-control valve stuck part-closed, restricting refrigerant to the indoor coil