Hisense AMW120TERJ holds NEA 5-tick certificate ELS-HES-AC250029 until 9 March 2028, pairing 6.34 kW cooling with a 5.79 weighted COP and 2,470 kWh yearly test use. Under SP Group's Q4 2026 billing tier, annual cost reaches S$770 while qualifying HDB buyers for S$400 Climate Vouchers.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Verify AMW120TERJ NEA Rating and Late 2026 Running Costs
Registered under NEA certificate ELS-HES-AC250029 until 9 March 2028, the Hisense AMW120TERJ earns 5 ticks at 6.34 kW output. Official test logs report 4.95 full-load COP, 6.35 part-load COP, and 5.79 weighted COP.
NEA prints S$667 on the tick sticker for 2,470 kWh yearly test use. Applying SP Group's Q4 2026 domestic electricity charge (31.16 cents/kWh with GST) lifts that same benchmark to S$770 annually. Because part-load efficiency reaches 6.35 COP, running one bedroom at 25 degrees overnight saves noticeably more power than cooling the entire flat together.
Compare AMW120TERJ Test Figures and Flat Suitability
Check verified NEA product figures alongside Singapore tariff assumptions before selecting indoor fan coil combinations:
Scroll to see more columns
| Benchmark item | AMW120TERJ figure | Verified test detail | Homeowner takeaway |
|---|---|---|---|
| NEA MELS certificate | ELS-HES-AC250029 (5 ticks) | Valid until 9 March 2028 | Qualifies for S$400 HDB vouchers |
| Cooling & COP split | 6.34 kW multi-split output | 4.95 full / 6.35 part / 5.79 weighted | Thrives during light overnight cooling |
| Annual power spend | 2,470 kWh yearly test use | S$667 NEA label / S$770 SP Q4 2026 | Calculated on 31.16 cents/kWh tariff |
| Recommended flat fit | 3-room or 4-room HDB flats | System 2 or compact System 3 | Avoid full-flat noon cooling load |
Match Room Heat Loads to Protect Part-Load COP
At 6.34 kW capacity, the AMW120TERJ excels across two overnight bedrooms where part-load efficiency hits 6.35 COP. Running a sunlit west-facing hall plus three bedrooms at noon pushes draw toward 4.95 COP.
Install heavy-gauge 22 SWG copper lines wrapped inside half-inch Armaflex closed-cell lagging so suction pipes stay dry. Ask installers to pressure-test R32 flare joints with dry nitrogen and verify condensate fall before sealing trunking. Monthly indoor mesh filter rinses also preserve coil airflow and compressor efficiency.
Plan Your AMW120TERJ Site Survey and Upkeep Cadence
Align Climate Voucher claims, clean copper piping specs, and routine maintenance right from handover day:
- Eligible HDB households redeem S$400 Climate Vouchers until 31 December 2027 on verified 5-tick aircon purchases. Confirm voucher balance before ordering indoor units.
- Confirm bracket clearance and breaker capacity with a S$30 on-site survey. That inspection fee drops to zero once installation or repair begins.
- Hold operating efficiency near 5.79 COP via regular general cleaning. Three or more units settle at S$25 apiece, two cost S$30 each, and one runs S$50 (14-day warranty).
- Chemical servicing clears sluggish drains at S$80 (1 blower), S$70 apiece (2 blowers), or S$60 apiece across larger multi-splits (60-day warranty). Heavy coil buildup needs dismantled overhauls costing S$150 for one zone, S$125 per zone on two, or S$115 each from three zones upward (90-day warranty).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Samsung · Wall-mounted
Coastal unit losing gas again: salt ate the pipe fitting
A corroded outdoor fitting thinned past the point where it can seal

Daikin · Cassette
Cassette not cooling: stuck gas-flow valve, not compressor
A flow-control valve stuck part-closed, restricting refrigerant to the indoor coil
Common Questions
Why does Hisense AMW120TERJ annual cost show S$667 on the NEA label versus S$770 here?
Is Hisense AMW120TERJ big enough for a four-room Singapore HDB flat?
Does Hisense AMW120TERJ qualify for S$400 NEA Climate Vouchers in Singapore?
How often should owners service a Hisense AMW120TERJ multi-split unit?