Daikin MKC70WVMG System 3 kWh and EZi Ownership Guide

Daikin MKC70WVMG delivers 6.92 kW cooling across three rooms under MELS-DAI-AC210061, reaching 6.65 part-load COP and 2,821 kWh yearly. Its high part-load rating keeps overnight 4-room HDB and condo sleep bills predictable.

On this page

Quick summary

Daikin MKC70WVMG carries NEA 5-tick listing MELS-DAI-AC210061 with 6.92 kW cooling, 6.65 part-load COP, and 2,821 kWh annual test draw. That equals S$879 yearly on Singapore's 31.16c/kWh GST-inclusive SP Group rate, pairing low overnight sleep bills with EZi CTKC and iSmile upkeep.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Understand MKC70WVMG 6.65 Part-Load COP and SP Group Bills

Approved under MELS-DAI-AC210061 until 29 September 2027, Daikin MKC70WVMG holds 5 NEA ticks at 6.92 kW. Its COP sits at 4.37 full load, 6.65 part load, and 5.74 weighted.

NEA prints 2,821 kWh yearly use (S$762 benchmark). Priced under Singapore's 31.16c/kWh GST-inclusive SP rate (Oct–Dec 2026), that annual test figure becomes S$879.

That gap between 4.37 full-load and 6.65 part-load COP shapes real bills. Cooling one 9,000 BTU bedroom nightly pulls 2.5 to 3.0 kWh (S$23 to S$28 monthly), while two bedrooms add S$45 to S$55.

Compare MKC70WVMG Ratings Against EZi and iSmile Ownership Needs

Daikin EZi CTKC WVMG blowers (CTKC25/35/50WVMG) commonly pair with System 3 setups alongside iSmile units. Check your indoor prefix using this guide:

Scroll to see more columns

Compare MKC70WVMG ratings against EZi and iSmile ownership needs summary table
Ownership detailMKC70WVMG dataNightly bedroom usePeak afternoon use
NEA MELS registrationMELS-DAI-AC210061 (5 ticks)Expires 29 September 20276.92 kW across three circuits
Efficiency spread5.74 weighted COP6.65 part-load overnight4.37 full-load under three heads
SP Group 31.16c billing2,821 kWh/yr (S$879/yr)~S$23 to S$28/mo (1 room)~S$45 to S$55/mo (2 rooms)
Indoor family matchingEZi CTKC WVMG seriesConfirm CTKC vs CTKM labelThermistors and PCBs differ by prefix
HDB Climate VouchersS$400 5-tick eligibleValid through December 2027Verify exact matched set on NEA portal

Pull Daikin Fault Codes from the Handset Before Calling

When an EZi or iSmile indoor lamp blinks green, point the Daikin handset at the wall receiver. Hold CANCEL down for five seconds until 00 appears.

Tap CANCEL slowly step by step while listening. Short chirps skip blank slots, whereas one long steady beep locks onto the active display code.

Record codes like U4 (indoor-outdoor transmission fault), U0 (refrigerant shortage warning), A3 (drain level control abnormality), or C4 (heat-exchanger thermistor fault). Hold CANCEL five seconds to exit.

Choose MKC70WVMG Check and Servicing Tiers for Your Home

Keep EZi and iSmile coils free of drain-pan jelly and dust using transparent published rates:

  • Arrange a S$30 fault visit whenever green lights blink. Proceeding with quoted repairs waives the visit fee and grants 30-day protection.
  • Standard maintenance starts at S$50 for one room. Twin units cost S$30 per head, and three-plus units cost S$25 per head (14-day cover).
  • Chemical servicing clears stale odours and weak airflow cleanly. Solo visits bill S$80, dual visits bill S$70 apiece, and three-plus cost S$60 each (60-day warranty).
  • Dismantled chemical overhauls strip heavy mould from blower wheels and pans. One room costs S$150, two cost S$125 each, and three or more cost S$115 each (90-day cover).

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Why does Daikin MKC70WVMG show 6.65 part-load COP versus 4.37 full-load COP?
Daikin MKC70WVMG achieves 6.65 part-load COP when cruising lightly for one or two bedrooms overnight, keeping SP bills low. Running all three indoor blowers flat out in afternoon heat pulls full load near 4.37 COP, so avoid switching unused rooms on during midday peaks.
Which Daikin indoor models match MKC70WVMG and why does the prefix matter?
Daikin EZi CTKC25/35/50WVMG indoor blowers pair commonly with System 3 setups alongside iSmile CTKS or CTKM families. Opening the front panel reveals the bottom-right sticker code, which determines exact thermistor and PCB compatibility during repairs.
How do owners retrieve a blinking fault code on Daikin MKC70WVMG?
Stand beneath the flashing Daikin blower, point the original handset at the receiver, and hold CANCEL for five seconds until 00 shows. Press CANCEL repeatedly until one long continuous beep sounds, then record the displayed fault code before holding CANCEL again to exit.
What does Daikin MKC70WVMG cost yearly on SP Group electricity rates?
NEA certifies MKC70WVMG at 2,821 kWh yearly (S$762 NEA label cost). At SP Group's Q4 2026 rate of 31.16 cents per kWh, that annual draw equals S$879, while cooling one 9,000 BTU bedroom nightly runs roughly S$23 to S$28 monthly.

Sources

Sources checked 27 Nov 2026

  1. NEA Registered Goods PortalNational Environment Agency (NEA) · Checked 27 Nov 2026
  2. SP Group Electricity Tariff InformationSP Group · Checked 27 Nov 2026
  3. NEA Climate Vouchers Aircon EligibilityNational Environment Agency and PUB · Checked 27 Nov 2026