Daikin MKM100ZVMG outputs 8.62 kW at 5.90 weighted COP and 3,154 kWh yearly under ELS-DAI-AC250008, billing S$983 annually at 31.16 cents/kWh. Verify ledge depth, 40A breaker headroom, and U0, U4, or A3 care before installing.

On this page

Quick summary

Daikin MKM100ZVMG carries NEA 5-tick listing ELS-DAI-AC250008 at 8.62 kW cooling, 5.90 weighted COP, and 3,154 kWh annual test draw. Using 31.16 cents/kWh regulated electricity pricing, that benchmark costs S$983 yearly, serving simultaneous living and bedroom cooling in large HDB and condo homes.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Measure MKM100ZVMG Output and Simultaneous SP Group Draw

Certified on ELS-DAI-AC250008 until 30 January 2028, Daikin MKM100ZVMG holds 5 NEA ticks at 8.62 kW. Laboratory COP sits at 5.25 full load, 6.33 part load, and 5.90 weighted.

NEA logs 3,154 kWh yearly draw and a S$851 label figure. Multiplied by SP Group bills at 31.16 cents per kWh (with GST), that annual test benchmark totals S$983.

High 5.25 full-load COP lets an 18,000 BTU hall and three bedrooms run together smoothly on hot weekends. Running one bedroom overnight draws 3.0 to 3.5 kWh (S$28 to S$33 monthly).

Verify 5-Room HDB, Executive Apartment, and Condo Fit

Executive apartments, sunlit 5-room corner HDB flats, and larger condos stretch smaller condensers when all rooms run together. Check these site constraints before ordering:

Scroll to see more columns

Verify 5-room HDB, executive apartment, and condo fit summary table
Site factorMKM100ZVMG specificationField requirementHomeowner check
NEA registrationELS-DAI-AC250008 (5 ticks)Valid until 30 Jan 20288.62 kW capacity for heavy multi-room demand
Full vs part efficiency5.25 full | 6.33 part COP5.90 weighted COPHandles peak daytime living plus bedroom cooling
Ledge depth and airflowLarge high-output chassisUnobstructed front dischargePrevent hot exhaust rebound inside narrow ledges
Electrical breaker checkHigher peak running amps40A main allowance preferredInspect older 30A resale DB boxes early
HDB Climate VoucherS$400 eligible 5-tick unitValid until December 2027Confirm System 4 or 5 indoor pairing keeps 5 ticks

Handle Daikin U0, U4, and A3 Alerts Cleanly

Heavy multi-split lines need thick 22 SWG copper in 0.5-inch closed-cell foam to prevent pipe sweat. Remote fault readouts narrow down issues fast.

Code U0 (refrigerant shortage warning) requires dry nitrogen leak testing on flare nuts before adding R32. Code U4 (indoor-outdoor transmission fault) often stems from oxidized ledge terminals or pinched wires.

Code A3 (drain level control abnormality) reflects biofilm clogging indoor trays or float switches. Routine tray cleaning prevents midnight bedroom drips and keeps drains flowing.

Book Your MKM100ZVMG Site Check and Servicing Tier

Check HDB breaker capacity and ledge depth before ordering hardware. Keep every CTKM indoor coil maintained on clear fixed pricing:

  • Schedule a S$30 inspection on site first. Snowflake deducts that fee from approved installs or repairs, backed by 30-day repair cover.
  • Routine servicing bills S$25 per coil across three or more rooms. Pairs pay S$30 apiece, and single rooms pay S$50 with 14-day protection.
  • Chemical washes remove musty smells or A3 tray slime. Three-plus heads cost S$60 each, two cost S$70 each, and one costs S$80 (60-day warranty).
  • Dismantled chemical overhauls clear deep blower mould completely. Sets of three or more run S$115 per coil, two run S$125 each, and one runs S$150 (90-day cover).

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

When is Daikin MKM100ZVMG better than smaller System 4 condensers in Singapore?
Daikin MKM100ZVMG supplies 8.62 kW with a strong 5.25 full-load COP, making it ideal for 5-room HDB flats, executive apartments, and condos cooling a large living room alongside three bedrooms simultaneously. Households cooling only bedrooms overnight run fine on smaller 7.35 kW sets.
Can every resale HDB flat support the electrical load of MKM100ZVMG?
Newer BTO flats generally carry 40A main electrical capacity suited for MKM100ZVMG, whereas certain older resale HDB blocks restrict total aircon running current. Checking your distribution box rating and ledge clearance during a S$30 site survey avoids failed installations.
What is the annual SP Group electricity cost for Daikin MKM100ZVMG?
NEA testing puts Daikin MKM100ZVMG at 3,154 kWh yearly (S$851 label benchmark). At the S$0.3116 per kWh SP Group tariff, that full benchmark equals S$983 per year, while one bedroom running eight overnight hours adds roughly S$28 to S$33 monthly.
What do U0, U4, and A3 alerts mean on Daikin MKM100ZVMG systems?
Daikin U0 flags a refrigerant shortage warning that calls for nitrogen leak detection on flare joints. U4 marks indoor-outdoor transmission loss along ledge wiring or boards, while A3 signals drain level trouble inside an indoor condensate tray.

Sources

Sources checked 27 Nov 2026

  1. NEA Registered Goods PortalNational Environment Agency (NEA) · Checked 27 Nov 2026
  2. SP Group Electricity Tariff InformationSP Group · Checked 27 Nov 2026
  3. HDB Aircon Installation GuidelinesHousing & Development Board (HDB) · Checked 27 Nov 2026