EuropAce ESAC MA3R215A carries NEA 5-tick certificate ELS-STR-AC250106 valid until 22 September 2028, pairing 5.68 kW output with 5.54 weighted COP and 2,184 kWh annual test draw. Under SP Group's Q4 2026 tariff, that benchmark costs S$681 yearly before S$400 HDB Climate Vouchers.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Break Down EuropAce 5.68 kW Efficiency and Late 2026 Tariff Math
Registered under NEA certificate ELS-STR-AC250106 through 22 September 2028, EuropAce ESAC MA3R215A holds 5 Green Ticks at 5.68 kW output. Weighted efficiency hits 5.54 COP from 5.12 full-load and 5.82 part-load ratings.
Annual benchmark consumption sits at 2,184 kWh, printed as S$590 on NEA's label. At Q4 2026 regulated tariffs (31.16 cents/kWh incl. GST), that test load totals S$681 yearly or about S$57 monthly.
Review Verified NEA Specifications and SP Group Benchmark Figures
Compare published NEA testing data for ESAC MA3R215A against current billing figures and voucher terms:
Scroll to see more columns
| Certificate metric | Verified ESAC MA3R215A figure | Bill or sizing effect | Singapore ownership note |
|---|---|---|---|
| NEA MELS registration | ELS-STR-AC250106 (5 ticks) | Valid until 22 September 2028 | Qualifies for S$400 HDB vouchers |
| Cooling capacity & COP | 5.68 kW | 5.54 weighted COP | 5.12 full load / 5.82 part load | Saves power when running 1-2 rooms |
| Annual NEA benchmark | 2,184 kWh/yr (S$590 label) | S$681/yr at 31.16 cents/kWh | Equals roughly S$57 monthly test load |
| Thermal output equivalent | ~19,380 BTU/hr total outdoor | Best for 2 bedrooms + 1 study | Avoid full-noon living hall overload |
Fit 5.68 kW Outdoor Capacity to HDB and Condo Bedrooms
At 5.68 kW (roughly 19,380 BTU/hr total cooling output), ESAC MA3R215A suits 3-room flats, compact BTO bedrooms, and two-bedroom condos. Running two 9,000 BTU bedrooms overnight stays comfortably inside its 5.82 part-load sweet spot.
Cooling three sunny bedrooms plus an open hall simultaneously stretches 5.68 kW past ideal diversity. Qualifying HDB owners can also apply S$400 vouchers toward verified 5-tick sets until end-2027.
Verify Pre-Install Piping Needs and Servicing Cadence
Keep part-load COP efficient year after year using clean pipe inspections and fixed servicing tiers:
- Confirm existing copper wall gauge and drain gradient with a S$30 pre-install check. That survey charge cancels out once installation proceeds under 30-day warranty.
- Schedule dry general servicing every quarter to prevent coil fouling. Charges stay flat at S$25 per head for three-plus heads, S$30 each for two, or S$50 for one (14-day warranty).
- Cut sticky humidity film off fins with chemical washes every year. Pricing runs S$60 per unit on three-plus sets, S$70 each on pairs, or S$80 on single heads (60-day warranty).
- Strip jelly slime inside drain pans during lease turnovers via dismantled overhauls. Full teardowns run S$115 per head on three-plus sets, S$125 on pairs, or S$150 single (90-day warranty).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

EuropAce · Wall-mounted
New wall unit drips in humid weather: bracket out of level
A mounting bracket set slightly out of level, moving the pan's low point off the outlet

Mitsubishi Electric · Wall-mounted
Trunking water drip: cracked drain elbow behind casing
A cracked drain elbow at a bend, losing water into the trunking below the tray