Gree GWC-09Charmo/O 5-Tick Single Split Guide

Certified under ELS-GAS-AC250031, GREE GWC-09Charmo/O delivers 2.65 kW cooling at 6.02 weighted COP and 969 kWh yearly draw. Review SP Group costs, compact bedroom fit, and servicing below.

On this page

Quick summary

GREE GWC-09Charmo/O holds active 5-tick approval ELS-GAS-AC250031 expiring 13 March 2028 at 2.65 kW cooling, 6.02 weighted COP, and 969 kWh annual use. Paying late-2026's 31.16-cent tariff puts benchmark electricity at S$302 yearly, while eligible HDB homes redeem S$400 vouchers.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Check Gree GWC-09Charmo/O Ratings and Yearly Power Cost

GREE GWC-09Charmo/O carries active 5-tick approval ELS-GAS-AC250031 expiring 13 March 2028 at 2.65 kW output. Lab efficiency records 5.22 full-load COP, 6.56 part-load COP, and 6.02 weighted COP.

Printed energy labels list 969 kWh annual use and a S$262 base estimate. Singapore's current 31.16-cent residential electricity charge brings 969 kWh to S$302 over twelve months, or S$25.20 monthly. Qualifying HDB addresses redeem S$400 in Climate Vouchers toward 5-tick splits through end-2027.

Compare Gree GWC-09Charmo/O Metrics and Flat Suitability

Compare official NEA registration numbers alongside bedroom dimensions and copper pipe specs. Checking these details first prevents buying an undersized unit:

Scroll to see more columns

Compare Gree GWC-09Charmo/O metrics and flat suitability summary table
Verified itemGREE GWC-09Charmo/O dataBenchmark contextSingapore room verdict
NEA label statusELS-GAS-AC250031 (5 ticks)Expires 13 Mar 2028Qualifies for S$400 HDB grant
Capacity and COP2.65 kW (~9,040 BTU)5.22 full / 6.56 part COP6.02 weighted COP savings
Yearly test draw969 kWh annual labelS$262 label estimateS$302 yearly at 31.16c tariff
Target space size9 to 13 sqm bedroom22 SWG + 0.5-in ArmaflexIdeal solo or study unit

Size 2.65 kW Cooling Cleanly for Bedrooms and Studies

Delivering roughly 9,040 BTU matches GREE GWC-09Charmo/O neatly to common bedrooms, helper quarters, and compact studies. Small inverters avoid harsh cycling overnight, holding 6.56 part-load COP steadily at 25 degrees.

Avoid stretching 2.65 kW across open dining halls or bright west-facing master suites. Keep curtains closed during afternoon sun hours, rinse filters monthly, and require thick-gauge 22 SWG copper tubes wrapped in dense half-inch foam and pulled to 500 microns before opening R32 valves.

Plan Gree GWC-09Charmo/O Servicing and Diagnostic Checks

Clean mesh filters and smooth drain flow keep overnight electricity low across humid Singapore months:

  • Upfront troubleshooting visits bill S$30 for single splits or S$80 on VRV gear. Approved repair jobs cancel this fee under 30-day warranty.
  • General cleans bill S$50 when solo. Two-room cleans run S$30/unit, and multi-room sets (3+) run S$25/unit with 14-day cover.
  • Alkaline coil washes remove stubborn grime. One bedroom costs S$80, two bedrooms cost S$70 per unit, while multi-room sets (3+) pay S$60/unit (60-day warranty).
  • Strip-down overhauls run S$150 solo, S$125 apiece for pairs, and S$115 apiece for 3+ heads under a 90-day warranty.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Why does NEA show S$262 for GREE GWC-09Charmo/O when SP Group bills reach S$302?
Older NEA stickers compute S$262 on 969 kWh using a legacy 27-cent benchmark figure. Under late-2026 SP Group domestic pricing of 31.16 cents for one kWh (GST included), 969 kWh reaches S$302 across twelve months.
What room size fits the 2.65 kW GREE GWC-09Charmo/O best in Singapore?
Delivering 2.65 kW (~9,040 BTU) cooling suits 9 to 13 sqm HDB common bedrooms, helper rooms, or enclosed studies cleanly. Sunny west-facing master bedrooms above 14 sqm or dining areas typically benefit from 3.5 kW single splits.
Can Singapore HDB owners use S$400 Climate Vouchers on GREE GWC-09Charmo/O?
Five-tick approval ELS-GAS-AC250031 allows eligible HDB owners to deduct S$400 with Climate Vouchers before 2028 begins. Confirm participating store registration and active household balance at checkout before paying equipment deposits.
How often should owners wash a GREE GWC-09Charmo/O bedroom unit?
Rinsing mesh filters monthly from floor level while booking quarterly general servicing keeps indoor airflow high and prevents slime buildup. Annual chemical washes clear deeper coil biofilm in humid bedrooms or homes with pets.

Sources

Sources checked 27 Nov 2026

  1. NEA Registered Goods PortalNational Environment Agency (NEA) · Checked 27 Nov 2026
  2. SP Group Electricity Tariff InformationSP Group · Checked 27 Nov 2026
  3. NEA Climate Friendly Households AirconsNational Environment Agency (NEA) · Checked 27 Nov 2026