LG Z2UQ18GFA1 System 2 5-Tick kWh and Ownership Guide

LG Z2UQ18GFA1 achieves 6.09 weighted COP and 6.77 part-load COP at 4.58 kW across two zones under ELS-LGE-AC250091. Annual NEA test usage totals 1,676 kWh (S$522 on SP rates), suiting 2-room and 3-room HDB flats.

On this page

Quick summary

LG Z2UQ18GFA1 holds NEA 5-tick approval ELS-LGE-AC250091 at 4.58 kW cooling, 6.09 weighted COP, and 6.77 part-load efficiency. Its 1,676 kWh yearly test figure bills S$522 under the Q4 31.16 cents/kWh SP rate. That fits 2-room and 3-room HDB flats well.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Review Z2UQ18GFA1 6.77 Part-Load COP and SP Bills

Listed via ELS-LGE-AC250091 through 13 July 2028, LG Z2UQ18GFA1 holds 5 NEA ticks at 4.58 kW capacity. Official COP hits 5.08 full load, 6.77 part load, and 6.09 weighted.

NEA lists a S$453 annual benchmark across 1,676 kWh. Applying Oct–Dec 2026 electricity charges at S$0.3116 per unit with GST, full test use comes to S$522.

That 6.77 part-load COP shines when cooling one bedroom overnight at 25 degrees. Daily eight-hour sleep draw runs 2.3 to 2.8 kWh (S$22 to S$26 monthly), or S$42 to S$50 for two rooms.

Match Z2UQ18GFA1 Specs and S$400 Climate Vouchers to HDB Flats

Owners of 2-room and 3-room HDB flats pairing Z2UQ18GFA1 with DualCool or ArtCool blowers gain strong efficiency plus voucher savings. Check key ownership metrics below:

Scroll to see more columns

Match Z2UQ18GFA1 specs and S$400 Climate Vouchers to HDB flats summary table
LG System 2 metricVerified Z2UQ18GFA1 specBill or rebate figureFlat planning note
NEA ELS listingELS-LGE-AC250091 (5 ticks)Valid until 13 July 20284.58 kW rated capacity across two zones
Weighted and part COP6.09 weighted | 6.77 part load5.08 full-load COPTop-tier overnight sleep efficiency
Yearly test consumption1,676 kWh (NEA S$453)S$522/yr at SP 31.16c/kWhRoughly S$22 to S$26/mo for 1 bedroom
Climate Voucher savingsS$400 HDB rebate eligibleRuns until December 2027Verify matched indoor-outdoor 5-tick code
Resale warranty boundaryNon-transferable LG coverTied to original owner addressInherited resale units require paid upkeep

Diagnose LG CH05 and CH38 Warnings Before Ordering Parts

LG systems surface fault circuits clearly via CH codes on wall screens or ThinQ alerts. Write down the display code and indoor suffix before ordering spare parts.

Code CH05 (communication error between the indoor and outdoor units) often follows storm trips, wet ledge terminals, or broken signal wires. Testing continuity comes before condemning outdoor boards.

Code CH38 (low refrigerant warning) calls for filter rinsing first and dry nitrogen leak testing at flare fittings next. Unclip ArtCool fascias gently so latches stay intact.

Plan Your Z2UQ18GFA1 Checks and Servicing Schedule

Verify retailer Climate Voucher status and 22 SWG copper lagging early. Keep indoor coils running smoothly with fixed flat maintenance rates:

  • Start with a S$30 field check before replacing parts. Approved jobs credit the fee back and include 30-day repair cover.
  • Basic maintenance charges S$50 for one coil and S$30 per coil for pairs. Larger sets of three-plus coils run S$25 each (14-day cover).
  • Chemical washes strip indoor slime cleanly at S$80 on one head. Pairs cost S$70 per head, and three or more rooms drop to S$60 per coil (60 days warranty).
  • Full dismantled overhauls restore fouled blower wheels at S$150 singly. Two-coil sets pay S$125 per coil, while three or more pay S$115 per coil (90 days warranty).

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Why does LG Z2UQ18GFA1 achieve 6.77 part-load COP in Singapore bedrooms?
LG Z2UQ18GFA1 uses dual-rotary inverter modulation that slows down calmly once a bedroom hits 25 degrees. That steady low-speed run lifts part-load COP to 6.77, keeping 1,676 kWh annual test usage at S$522 under the 31.16 cents/kWh SP tariff.
What should owners test first when LG Z2UQ18GFA1 shows CH05 or CH38?
Code CH05 marks indoor-outdoor communication failure, so technicians test terminal power and signal wiring before condemning outdoor PCBs. Code CH38 signals a low refrigerant warning requiring filter checks followed by nitrogen pressure testing on flare connections.
Does LG aircon warranty transfer to buyers of resale HDB flats?
LG Singapore warranty applies strictly to the original purchaser and registered installation address. Resale buyers inheriting an installed Z2UQ18GFA1 set should budget for independent servicing and out-of-warranty repairs unless LG confirms transferability in writing.
Can 2-room and 3-room HDB owners redeem S$400 Climate Vouchers on LG Z2UQ18GFA1?
Singaporean and PR HDB households redeem S$400 NEA Climate Vouchers on verified 5-tick LG Z2UQ18GFA1 packages until December 2027. Confirm retailer participation and verify the paired indoor units maintain 5-tick registration before checkout.

Sources

Sources checked 27 Nov 2026

  1. NEA Registered Goods PortalNational Environment Agency (NEA) · Checked 27 Nov 2026
  2. SP Group Electricity Tariff InformationSP Group · Checked 27 Nov 2026
  3. NEA Climate Vouchers Aircon EligibilityNational Environment Agency and PUB · Checked 27 Nov 2026