Mitsubishi Heavy SRC10YYS2-W8 Single Split kWh Guide

Mitsubishi Heavy Industries SRC10YYS2-W8 pairs 2.53 kW single-split output with 5.56 weighted COP and 993 kWh test usage under ELS-WKH-AC250131. Review late-2026 SP Group bills, bedroom sizing, and servicing rates below.

On this page

Quick summary

Mitsubishi Heavy Industries SRC10YYS2-W8 holds active NEA registration ELS-WKH-AC250131 until 23 December 2028 at 5 ticks, 2.53 kW output, and 5.56 weighted COP. Benchmark use totals 993 kWh yearly, costing S$309 on late-2026 SP Group bills while qualifying for S$400 HDB Climate Vouchers.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Review SRC10YYS2-W8 Efficiency and SP Group Power Bills

Active until 23 December 2028 under NEA listing ELS-WKH-AC250131, Mitsubishi Heavy Industries SRC10YYS2-W8 achieves 5 ticks at 2.53 kW capacity. Rated test figures record 4.80 full-load COP, 6.06 part-load COP, and 5.56 weighted COP.

Published test power sits at 993 kWh annually, printed as S$268 on the green label. At 31.16 cents (GST included) under SP Group Q4 tariffs, yearly test power runs S$309, or roughly S$26 monthly. Eligible HDB homes also claim S$400 vouchers on 5-tick sets through late 2027.

Compare SRC10YYS2-W8 Specs Against Bedroom Cooling Needs

Match SRC10YYS2-W8 certified figures with HDB bedroom heat load and electrical limits before ordering:

Scroll to see more columns

Compare SRC10YYS2-W8 specs against bedroom cooling needs summary table
Assessment metricSRC10YYS2-W8 ratingTariff or validity basisSingapore home note
NEA MELS registrationELS-WKH-AC250131 (5 ticks)Valid to 23 Dec 2028Verify exact model code on invoice
Cooling & COP profile2.53 kW (~8,630 BTU/h)4.80 full / 6.06 part COP5.56 weighted COP suits overnight sleep
Annual test energy993 kWh benchmark drawS$268 NEA; S$309 SP Q4 2026About S$26/month at 31.16c GST-incl.
Flat & voucher pairingCommon bedroom or studyS$400 Climate Voucher eligibleFits 90 to 140 sq ft enclosed rooms

Match 2.53 kW Output and Mitsubishi Heavy Parts Support

Delivering 2.53 kW cooling lets SRC10YYS2-W8 serve shaded HDB common rooms, nurseries, or closed studies without rapid short-cycling. Sunlit master rooms above 150 square feet typically need a 3.49 kW model. Measure spare HDB ledge clearance and check remaining DB breaker capacity before mounting another condenser.

Mitsubishi Heavy Industries (SRC outdoor, SRK indoor) is separate from Mitsubishi Electric Starmex and shares zero boards or fault tables. Local MHI stockists are narrower. Note E5 signal errors, E9 drain trips, or E16 fan alerts clearly and check part lead times before booking.

Verify SRC10YYS2-W8 Installation Checks and Upkeep Rates

Protect part-load inverter efficiency in damp bedrooms with timely cleaning and flat Snowflake rates:

  • Diagnostic checks or site visits run S$30 for split units, or S$80 on VRV setups. Proceeding waives this fee under 30-day warranty.
  • Routine maintenance bills S$50 for one split unit. Paired blowers run S$30 each, while three-plus blowers run S$25 apiece with a 14-day warranty.
  • Chemical coil flushing clears odour buildup at S$80 for one indoor unit. Twin jobs bill S$70 per unit, and three-plus jobs bill S$60 per unit (60-day warranty).
  • Dismantled chemical overhauls clear blocked drain trays at S$150 for one room. Two rooms cost S$125 per coil, while three or more cost S$115 per coil (90-day cover).

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Which Singapore bedrooms suit the 2.53 kW Mitsubishi Heavy SRC10YYS2-W8?
Delivering 2.53 kW (~8,630 BTU/h) cooling matches shaded 90 to 140 square foot HDB common rooms, studies, or helper bedrooms. Sun-exposed master bedrooms above 150 square feet usually step up to 3.49 kW units.
Why does SRC10YYS2-W8 list S$268 on its NEA sticker versus S$309 yearly?
Printed NEA labels calculate annual bills using an older 27-cent benchmark rate. Multiplying 993 kWh against SP Group's 31.16 cents Q4 tariff (GST included) brings yearly benchmark electricity to S$309.
Are Mitsubishi Heavy SRC10YYS2-W8 parts interchangeable with Mitsubishi Electric Starmex?
Mitsubishi Heavy Industries uses SRC and SRK hardware with E-prefix fault tables, sharing zero boards, motors, or spare components with Mitsubishi Electric Starmex. Always give the full brand name before booking repairs.
Can an HDB owner claim Climate Vouchers on SRC10YYS2-W8?
Certified under 5-tick listing ELS-WKH-AC250131 until 23 December 2028, Mitsubishi Heavy SRC10YYS2-W8 qualifies eligible Singapore HDB households for S$400 Climate Vouchers at participating retailers through 31 December 2027.

Sources

Sources checked 27 Nov 2026

  1. NEA Registered Goods PortalNational Environment Agency (NEA) · Checked 27 Nov 2026
  2. SP Group Electricity Tariff InformationSP Group · Checked 27 Nov 2026
  3. NEA Climate Vouchers Aircon GuideNational Environment Agency (NEA) · Checked 27 Nov 2026