Quick summary
Registered under NEA listing ELS-MIT-AC260040 until July 2029, Mitsubishi Electric MUY-GA13VF pairs 3.61 kW output with 5.66 weighted COP and 1,407 kWh yearly draw. Running that load on SP Group tariffs costs S$438 annually, while qualifying HDB homes apply S$400 vouchers.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Check MUY-GA13VF Efficiency Numbers and SP Group Yearly Cost
Certificate ELS-MIT-AC260040 stays valid until 14 July 2029. It rates Mitsubishi Electric MUY-GA13VF at 5 green ticks with 3.61 kW cooling (~12,320 BTU). Efficiency stands at 4.90 full-load COP, 6.17 part-load COP, and 5.66 weighted COP.
Annual benchmark consumption sits at 1,407 kWh, printing S$380 on the official label. Residential tariffs stand at 31.16 cents/kWh with GST added, turning 1,407 kWh into S$438 per year.
Notice how 4.90 full-load COP sustains steady daytime efficiency during afternoon heat gain. Eight-hour evening bedroom runs at 25 degrees typically consume 2.7 to 3.3 kWh, averaging roughly S$26 to S$31 per month.
Compare MUY-GA13VF Benchmarks, Wiring, and Voucher Value
Review verified NEA numbers against local room demand, installation specs, and HDB grant eligibility:
Scroll to see more columns
| Assessment dimension | MUY-GA13VF rated figure | Singapore home benchmark | Selection impact |
|---|---|---|---|
| NEA 5-tick approval | ELS-MIT-AC260040 (Jul 2029) | 3.61 kW | 5.66 weighted COP | Strong 4.90 full-load daytime margin |
| Label vs SP Group bill | 1,407 kWh yearly usage | S$380 label vs S$438 SP rate | ~S$26 to S$31 monthly night spend |
| Recommended room zone | ~12,320 BTU/h class | 150 to 200 sq ft rooms | Suits sunny masters or work offices |
| Piping & HDB voucher | Eligible 5-tick HDB unit | S$400 voucher up to Dec 2027 | Fit 22 SWG copper + 1/2-inch lagging |
Compare MUY-GA13VF Against 2.63 kW and 4.26 kW Single Splits
Sitting squarely between 9k and 15k models, MUY-GA13VF solves warm 150 to 200 sq ft rooms cleanly. Shaded bedrooms under 130 sq ft belong on the 2.63 kW MUY-GA10VF. Wide loft zones above 200 sq ft call for a 4.26 kW MUY-GA15VF split.
Oversizing a 3.61 kW unit inside a tiny 95 sq ft room causes rapid chilling before moisture clears, leaving bedding clammy. Match capacity carefully to sunlit glass area, ceiling height, and occupancy. Running 22 SWG copper piping also avoids flare cracks.
Confirm bracket clearances and isolator rating via a S$30 site inspection (waived on job completion; $80 VRV). Eligible HDB owners also apply S$400 vouchers up to December 2027.
Prepare a Practical Cleaning Schedule for MUY-GA13VF
Dust the indoor grille from safe floor height every two to three weeks without climbing onto ledges or touching 230V terminals. Book deeper servicing on schedule:
- Routine brush-and-vacuum cleaning runs S$50 on a single MUY-GA13VF, dropping to S$30/head for two heads and S$25/head across three or more (14-day warranty).
- Chemical flushing removes greasy condensate gel for S$80 (one head), S$70/head (two heads), or S$60/head (three-plus), covered for 60 days.
- Deep dismantled cleaning restores blocked drums at S$150 (one head), S$125/head (two heads), or S$115/head (three-plus), covered for 90 days.
- Completed repairs following S$30 diagnostic checks carry 30-day warranty protection.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Mitsubishi Electric · Multi-split
Outdoor ledge dripping downstairs: split drain pipe stub
Split outdoor PVC condensate drain stub spilling backed-up water across the ledge

Daikin · Wall-mounted
Water stain down the wall: blocked rear drain trough
Biofilm jelly choking the hidden rear auxiliary drain trough behind the evaporator coil, spilling condensate down the plastered wall while the main trunking pipe stayed intact
Common Questions
How does MUY-GA13VF compare with a 9,000 BTU single split for electricity bills?
Can MUY-GA13VF cool a west-facing HDB master bedroom smoothly at night?
What happens if a 3.61 kW single split is fitted into a tiny bedroom?
How often should Singapore homeowners wash a Mitsubishi MUY-GA13VF blower?