Mitsubishi Starmex MXY-2H20VF System 2 Cost and kWh

Mitsubishi Electric MXY-2H20VF cools two rooms at 4.51 kW with 6.01 weighted COP and 1,664 kWh annual test use under MELS-MIT-AC190010. Compact 2-room flexi and 3-room HDB owners qualify for S$400 Climate Vouchers and steady SP bills.

On this page

Quick summary

Mitsubishi Electric MXY-2H20VF holds NEA 5-tick listing MELS-MIT-AC190010 at 4.51 kW cooling and 6.01 weighted COP. Its 1,664 kWh annual test use bills S$519 under SP Group's 31.16 cents/kWh rate. Eligible HDB buyers also claim S$400 Climate Vouchers.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Check MXY-2H20VF Capacity and Annual SP Group Bills

Registered under MELS-MIT-AC190010 through 27 March 2028, MXY-2H20VF carries 5 NEA ticks at 4.51 kW. Test efficiency stands at 5.01 full load, 6.67 part load, and 6.01 weighted COP.

NEA prints 1,664 kWh annual test use and a S$449 label benchmark. Applying the Oct–Dec 2026 SP tariff of S$0.3116/kWh (GST-inclusive), yearly testing equals S$519.

One 9,000 BTU bedroom running eight hours nightly at 25 degrees draws 2.4 to 2.9 kWh. Monthly bills add S$22 to S$27 for one room, or S$43 to S$52 for two.

Match MXY-2H20VF Output to 2-Room Flexi and 3-Room HDB Flats

Compact 2-room flexi BTO units and 3-room resale flats often pair MXY-2H20VF with two MSXY-FP blowers. Review key capacity, rebate, and ledge details below:

Scroll to see more columns

Match MXY-2H20VF output to 2-room flexi and 3-room HDB flats summary table
Evaluation factorMXY-2H20VF benchmarkTariff or voucher figureCompact HDB takeaway
NEA MELS certificateMELS-MIT-AC190010 (5 ticks)Expires 27 March 20284.51 kW capacity across two indoor ports
COP test breakdown6.01 weighted COP5.01 full | 6.67 part loadEfficient solo bedroom cruising overnight
SP Q4 2026 annual draw1,664 kWh yearly labelS$519/yr (NEA prints S$449)About S$22 to S$27 monthly for 1 bedroom
HDB rebate eligibilityS$400 Climate VouchersValid through December 2027Confirm 5-tick indoor coil pairing on invoice
Ledge and circuit fitCompact single-fan chassisStandard 15A/20A isolatorLeave front ledge space clear for exhaust air

Starmex indoor heads report alerts via operation lamp flashes rather than wall screen digits. Watch two flash cycles, then retrieve the stored code using the original remote's recessed CHECK button.

Universal remotes cannot open diagnostic mode. Code E6 (indoor-outdoor communication receiving error) often comes from loose ledge terminals, aged signal cables, or mode clashes between rooms.

Confirm both blowers run Cool mode together before booking repair. When rooms turn warm slowly without E6, book dry nitrogen leak testing prior to adding R32.

Plan Your MXY-2H20VF Inspection and Servicing Schedule

Check drain slope and S$400 voucher paperwork before install day. Keep both blowers clean on predictable fixed rates:

  • Request a S$30 on-site survey before buying or fixing parts. That fee drops off once quoted work proceeds, and repairs include 30-day cover.
  • General cleaning runs S$50 solo, S$30 each for pairs, or S$25 per head across three-plus blowers. Every routine wash carries 14-day cover.
  • Musty coils need chemical servicing at S$80 for one room or S$70 each for two. Three-plus rooms drop to S$60 apiece with 60-day cover.
  • Stubborn blower slime needs a dismantled chemical overhaul at S$150 singly or S$125 each for pairs. Larger sets drop to S$115 per head (90-day cover).

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Is Mitsubishi MXY-2H20VF strong enough for a 2-room flexi or 3-room HDB flat?
Mitsubishi MXY-2H20VF outputs 4.51 kW across two ports, comfortably cooling a master bedroom alongside a living room or second bedroom in 2-room flexi and 3-room HDB flats. Pairing two 9,000 BTU blowers preserves crisp afternoon cooling even when both rooms run simultaneously.
How much does MXY-2H20VF cost on SP Group electricity rates?
NEA records 1,664 kWh annual test draw for MXY-2H20VF, which equals S$519 yearly under the 31.16 cents/kWh regulated SP rate (NEA prints S$449). Running one 9,000 BTU bedroom for eight sleep hours at 25 degrees typically adds S$22 to S$27 per monthly bill.
How do homeowners check an E6 code on Mitsubishi Starmex MXY-2H20VF?
Starmex wall units flash the operation lamp rather than showing digits directly. Count flashes across two pauses, then hold the recessed CHECK button on the original Mitsubishi remote within two metres. Code E6 flags indoor-outdoor communication issues checked at wiring and terminals before board replacement.
Can HDB buyers apply S$400 Climate Vouchers to Mitsubishi MXY-2H20VF?
Eligible Singaporean and PR HDB households deduct S$400 via NEA Climate Vouchers on 5-tick MXY-2H20VF sets through December 2027. Always verify that your retailer participates in the scheme and that your exact indoor blower pairing retains 5-tick certification before ordering.

Sources

Sources checked 27 Nov 2026

  1. NEA Registered Goods PortalNational Environment Agency (NEA) · Checked 27 Nov 2026
  2. SP Group Electricity Tariff InformationSP Group · Checked 27 Nov 2026
  3. NEA Climate Vouchers Aircon EligibilityNational Environment Agency and PUB · Checked 27 Nov 2026