Quick summary
TCL FMA-27I4HD/DVO carries NEA 5-tick certificate ELS-FEL-AC240037 with 7.16 kW cooling, 5.62 weighted COP, and 2,780 kWh annual test draw until 20 May 2027. SP Group bills run S$866 yearly on that benchmark, while eligible HDB homes apply S$400 Climate Vouchers.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Verify NEA 5-Tick Metrics and SP Group Annual Cost
Listed under NEA certificate ELS-FEL-AC240037 until 20 May 2027, TCL FMA-27I4HD/DVO earns 5 green ticks. It outputs 7.16 kW cooling with 4.90 full-load COP, 6.10 part-load COP, and 5.62 weighted COP.
Annual benchmark consumption sits at 2,780 kWh, printed as S$751 on the standard tick label. Applying SP Group's Q4 2026 GST-inclusive 31.16 cents/kWh tariff brings that annual benchmark to S$866.
That equals around S$72 monthly on average test draw. Eligible HDB households also apply S$400 NEA Climate Vouchers valid until late December 2027.
Compare TCL FMA-27I4HD/DVO Specs and Flat Sizing Fit
Review official NEA performance figures alongside Singapore household usage notes:
Scroll to see more columns
| Benchmark item | TCL FMA-27I4HD/DVO | Published value | Singapore home note |
|---|---|---|---|
| NEA MELS certificate | ELS-FEL-AC240037 (5 ticks) | Expires 20 May 2027 | Qualifies for S$400 HDB vouchers |
| Rated cooling output | Multi Split 7.16 kW | ~24,400 BTU aggregate | Fits three bedrooms or 3-room flat |
| Efficiency curve | 6.10 part / 4.90 full | 5.62 weighted COP | Efficient overnight single-zone draw |
| Annual test energy | 2,780 kWh NEA rating | S$866 SP / S$751 label | Calculated at 31.16c Q4 2026 rate |
| Estimated 8h bedroom | One room at 25 degrees | ~S$26 to S$32 monthly | Based on 6.10 part-load efficiency |
Match 7.16 kW Capacity to HDB and Condo Rooms
At 7.16 kW total output, this outdoor unit handles three standard HDB bedrooms during staggered evening sleep cycles. Compact three-room flats and study-plus-bedroom condo layouts also cool steadily without strain.
Large west-facing four-room living spaces running alongside three bedrooms simultaneously exceed 7.16 kW around noon. Verify wall glazing heat load and ledge space before ordering.
Plan Installation Surveys and Quarterly Servicing Cadence
Protect part-load COP and indoor coil airflow from day one with structured inspections:
- Schedule a S$30 layout survey (S$80 for VRV configurations) to check ledge clearance and pipe slope. Snowflake deducts that inspection cost upon installation.
- Preserve 6.10 part-load efficiency through routine general cleaning. One blower costs S$50, two cost S$30/unit, and three or more cost S$25/unit under a 14-day workmanship guarantee.
- Clear oily bedroom residue mid-year using chemical servicing. Single-blower cleans cost S$80, two-unit visits charge S$70/unit, and three or more units charge S$60/unit (60-day guarantee).
- Heavy post-renovation dust needs a dismantled chemical overhaul. Individual units run S$150, paired setups run S$125/unit, and larger multi-splits run S$115/unit under a 90-day guarantee.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Mitsubishi Electric · Multi-split
Outdoor ledge dripping downstairs: split drain pipe stub
Split outdoor PVC condensate drain stub spilling backed-up water across the ledge

Gree · Wall-mounted
Gree F0 on a rusted condenser: refrigerant shortage
R32 refrigerant shortage triggering Gree F0 protection from corroded evaporator return bends