Quick summary
Toshiba error code 25 signals refrigerant leak detection on inverter aircons in Singapore. Switch off the unit immediately if error 25 returns with weak cooling, indoor frost, hissing sounds, or outdoor-unit breaker trips so technicians can perform dry nitrogen pressure testing.
On-site fault check: $30 ($80 VRV), waived if you proceed with repair · See diagnosis & repair
Understand Toshiba Error Code 25 Stop Warnings
Toshiba 25 indicates active refrigerant leak detection under the Refrigerant / Pressure Fault category. Running a starved inverter compressor raises discharge heat rapidly and risks costly outdoor motor burnout.
Stop using the aircon whenever error 25 returns alongside warm air, coil frost, hissing pipes, or outdoor breaker tripping. Repeated power resets will not refill lost refrigerant.
Check Safe Indoor Clues Before Calling Technicians
Note these symptom pairings indoors before powering off the system for repair triage:
Scroll to see more columns
| Symptom with Toshiba 25 | Safe indoor action | Probable mechanical cause | Proper Singapore resolution |
|---|---|---|---|
| Warm room airflow | Power down via remote & isolator | Flare joint or coil leak | Book S$30 pressure leak diagnosis |
| Frost across indoor fins | Turn off to thaw naturally | Low gas charge or blocked mesh | Rinse filters once ice melts |
| Audible pipe hissing | Shut wall isolator immediately | Active refrigerant gas escape | Hold off; arrange nitrogen testing |
| Outdoor breaker tripping | Stop resetting distribution board | Overheated compressor or wire short | Book licensed electrical fault check |
Follow Safe Resident Boundaries and Leak Repair Steps
Residents may safely switch off wall isolators and rinse dusty plastic filters from floor level once ice melts. Never open 230V terminal covers, probe live boards, or step onto HDB ledges to check hissing outdoor pipes.
Technicians pressurise circuits using dry nitrogen, trace tiny leaks across flares or U-bends, repair leaking copper, pull a deep vacuum, and weigh exact refrigerant charge per specification.
Book Leak Testing and Compare Toshiba Servicing Tiers
Resolve active refrigerant leaks first, then restore clean coil airflow across connected bedrooms:
- Diagnostic testing costs S$30 on residential splits or S$80 for commercial VRV units, waiving the check charge when repairs move forward with a 30-day warranty.
- Post-repair maintenance keeps clean airflow steady: general washes charge S$50 (1 blower), S$30 each (2 blowers), or S$25 each (3+ blowers) for 14 days coverage.
- Chemical evaporator washes clear matted dirt hiding fault symptoms at S$80 (1 blower), S$70 each (2 blowers), or S$60 each (3+ blowers) with 60 days warranty.
- Dismantled overhauls clear iced-up fan cages at S$150 (1 blower), S$125 each (2 blowers), or S$115 each (3+ blowers) carrying 90 days warranty.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Daikin · Wall-mounted
Daikin J6 outdoor red LED: bad thermistor, not condenser
Open-circuit Daikin outdoor heat-exchanger thermistor halting multi-split cooling via outdoor safety protection while the inverter compressor stays healthy

Samsung · Wall-mounted
Coastal unit losing gas again: salt ate the pipe fitting
A corroded outdoor fitting thinned past the point where it can seal
Common Questions
Can homeowners just top up gas when Toshiba displays error code 25?
Why does Toshiba error code 25 sometimes trip the electrical breaker?
What safe checks can a resident do before a technician arrives for code 25?
Does Snowflake charge an inspection fee if I proceed with a Toshiba 25 repair?