Toshiba RAS-2M21U2ACVG-SG Multi Split 5-Tick Guide

Toshiba RAS-2M21U2ACVG-SG retains active 5-tick approval under MELS-CAR-AC190046 with 4.51 kW capacity, 5.76 weighted COP, and 1,717 kWh annual benchmark consumption. Review SP Group bills, room sizing boundaries, and servicing schedules below.

On this page

Quick summary

Toshiba RAS-2M21U2ACVG-SG carries NEA 5-tick listing MELS-CAR-AC190046 until November 2028 at 4.51 kW cooling capacity and 5.76 weighted COP. Standard 1,717 kWh benchmark electricity translates to S$535 annually on Q4 SP Group tariffs, fitting two-bedroom HDB and condo upgrades well.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Check RAS-2M21U2ACVG-SG NEA Ratings and SP Group Bills

Certificate MELS-CAR-AC190046 certifies Toshiba RAS-2M21U2ACVG-SG at 5 ticks until 20 November 2028. Rated cooling delivers 4.51 kW, scoring 5.13 full-load COP, 6.18 part-load COP, and 5.76 weighted COP.

Annual benchmark draw stands at 1,717 kWh, shown as S$464 on NEA labels. At Q4 2026 SP Group rates (S$0.3116 per kWh, GST included), that annual test equals S$535 or S$44.60 monthly.

Eligible HDB owners also apply S$400 Climate Vouchers running until year-end 2027.

Compare RAS-2M21U2ACVG-SG Metrics and Household Fit

Inspect certified efficiency figures alongside Singapore billing and two-room layout suitability:

Scroll to see more columns

Compare RAS-2M21U2ACVG-SG metrics and household fit summary table
Performance factorRAS-2M21U2ACVG-SG valueBilling or voucher noteOwner decision takeaway
NEA registrationMELS-CAR-AC190046 (5 ticks)Valid until 20 November 2028Qualifies for S$400 flat vouchers
Cooling and efficiency4.51 kW | 5.76 weighted COP5.13 full / 6.18 part loadSuits steady overnight room cooling
Yearly energy cycle1,717 kWh test benchmarkS$464 NEA vs S$535 SP Q4Only S$9 yearly above newer P2
Indoor blower pairingTwo bedrooms (9k + 9k/12k)Keep draw in part-load bandUnsuitable for sunlit 3-room halls

Evaluate RAS-2M21U2ACVG-SG Fit for Two-Room HDB Flats

Delivering 4.51 kW (about 15,400 BTU/h), this multi split suits master and common bedrooms in 3-room flats or compact condos. Running two rooms softly overnight holds inverter load inside its 6.18 part-load band.

Compared against newer RAS-2M21P2ACVG-SG (6.04 weighted COP at 4.58 kW and 1,688 kWh), this U2 set draws just 29 kWh (S$9) more per year. Keep sunny living spaces off this condenser.

Book Routine Toshiba Servicing to Preserve Part-Load COP

Matted dust films across blower barrels quietly drag part-load efficiency down long before error codes appear:

  • Schedule Snowflake's S$30 pre-work check before replacing parts. Approved installs or repairs waive that charge (30-day warranty).
  • Two-unit Toshiba servicing charges S$60 combined (S$30 each). Lone splits run S$50, while larger multi-splits pay S$25 per unit (14-day workmanship cover).
  • Biofilm flushing via chemical wash charges S$80 for a single split, S$70 per unit on pairs, and S$60 across bigger sets (60-day cover).
  • Blocked trays need full strip-downs: one FCU costs S$150, dual FCUs cost S$125 per coil, and larger jobs cost S$115 per coil carrying a 90-day warranty.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

What separates Toshiba RAS-2M21U2ACVG-SG from RAS-2M21P2ACVG-SG in running cost?
Toshiba RAS-2M21U2ACVG-SG draws 1,717 kWh annually versus 1,688 kWh for RAS-2M21P2ACVG-SG under NEA testing. Across SP Group's Q4 2026 tariff, that 29 kWh gap equals roughly S$9 yearly while both keep 5 ticks.
How long does MELS-CAR-AC190046 registration remain valid in Singapore?
NEA certificate MELS-CAR-AC190046 keeps Toshiba RAS-2M21U2ACVG-SG registered at 5 green ticks until 20 November 2028. Buyers checking Climate Voucher or replacement quotes should verify active registration dates before purchasing remaining showroom stock.
Can RAS-2M21U2ACVG-SG run two bedrooms simultaneously on warm Singapore nights?
Twin 9,000 BTU bedrooms running together at 25 degrees fit inside the 4.51 kW outdoor rating smoothly. Keeping curtains drawn and clean filters preserves the 6.18 part-load COP without pushing inverter speed.
How much should cleaning a two-unit Toshiba RAS-2M21U2ACVG-SG setup cost?
Routine twin-unit cleaning runs S$30 per head (S$60 total) with a 14-day workmanship guarantee. Deep chemical coil washes run S$70 per unit (S$140 pair), while full dismantled overhauls cost S$125 per unit.