Toshiba RAS-3M31P2ACVG-SG Multi Split kWh Guide

Registered under NEA certificate ELS-CAR-AC250062, Toshiba RAS-3M31P2ACVG-SG delivers 6.03 kW cooling across Singapore multi-room flats at 5.78 weighted COP. Review current tariff bill calculations, bedroom capacity limits, and servicing schedules below.

On this page

Quick summary

Toshiba RAS-3M31P2ACVG-SG carries NEA 5-tick certificate ELS-CAR-AC250062 until 10 April 2028, pairing 6.03 kW capacity with a 5.78 weighted COP and 2,318 kWh yearly test draw. Under SP Group domestic billing, that benchmark runs S$722 annually before S$400 HDB Climate Vouchers.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Review Toshiba RAS-3M31P2ACVG-SG kWh and Bill Math

Toshiba RAS-3M31P2ACVG-SG holds active NEA 5-tick approval ELS-CAR-AC250062 until 10 April 2028. Rated cooling reaches 6.03 kW with 4.99 full-load COP and 6.31 part-load COP. Its weighted efficiency settles at 5.78 COP.

Official test figures list 2,318 kWh per year and an S$626 NEA label cost. Multiplying 2,318 kWh by SP Group's Q4 2026 GST-inclusive domestic tariff (31.16 cents/kWh after GST) equals S$722 yearly. That works out near S$60 monthly on standard test usage.

Eligible HDB flats buying verified 5-tick models can redeem S$400 Climate Vouchers before end-2027.

Compare Official NEA Metrics and Flat Sizing Fit

Review verified NEA ratings, tariff maths, and bedroom pairing limits side by side:

Scroll to see more columns

Compare official NEA metrics and flat sizing fit summary table
Metric categoryVerified data pointBill or sizing meaningOwner planning takeaway
NEA registrationELS-CAR-AC250062 (5 ticks)Valid through 10 April 2028Eligible for S$400 HDB vouchers
Cooling and COP6.03 kW | 5.78 weighted COP4.99 full-load; 6.31 part-loadThrives during low overnight loads
Annual test energy2,318 kWh NEA benchmarkS$626 NEA label vs S$722 SP Q4Roughly S$60 monthly under SP 31.16c
Capacity allocationAbout 20,575 BTU/h total poolSuits three 9,000 BTU bedroomsAvoid pairing large living spaces

Match 6.03 kW Output to HDB and Condo Rooms

At 6.03 kW (~20,575 BTU/h), this outdoor unit suits 3-room or 4-room HDB bedrooms cleanly. Running one or two rooms overnight captures its peak 6.31 part-load COP efficiency.

Avoid cooling three sunlit bedrooms and a wide living room together on 6.03 kW. Heavy simultaneous demand forces compressors toward 4.99 full-load operation and slows room pulldown. Assign an independent unit for big open living areas.

Plan Installation Survey and Toshiba Servicing Cadence

Protect part-load economy across Singapore humidity with timed inspections and bundle servicing:

  • Site inspections run S$30 for residential split layouts (or S$80 when assessing VRV condensers). Check fees convert straight into project credits whenever installation or repair proceeds (30-day warranty).
  • Three-room general washes run S$75 total (S$25 per room) with 14-day protection. Paired rooms bill S$30 per room, while lone units cost S$50.
  • Three-room chemical washes total S$180 (S$60 per unit) backed for 60 days. Dual washes run S$70 each, while single units cost S$80.
  • Three-room dismantled overhauls cost S$345 total (S$115 per head) under 90-day coverage. Two stripped coils bill S$125 each, while one head costs S$150.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

How much does Toshiba RAS-3M31P2ACVG-SG cost to run per month under SP Group rates?
Running NEA's 2,318 kWh annual test cycle against SP Group's Q4 2026 GST-inclusive 31.16 cents/kWh tariff equals S$722 per year, or about S$60 monthly. Actual bills depend on indoor temperature setpoints and how many rooms run nightly.
Can Toshiba RAS-3M31P2ACVG-SG cool a 4-room HDB living room and three bedrooms together?
Delivering 6.03 kW (around 20,575 BTU/h) comfortably cools three sleeping bedrooms running staggered hours, whereas adding a large West-facing living hall simultaneously overloads capacity. Most 4-room flats assign dedicated units for heavy living spaces.
Do HDB households qualify for Climate Vouchers on Toshiba RAS-3M31P2ACVG-SG?
Qualifying Singapore HDB residences holding unused S$400 NEA Climate Vouchers may redeem them toward 5-tick certificate ELS-CAR-AC250062 before December 2027. Participating retailers verify flat eligibility and valid registration numbers directly at checkout.
How often should Singapore owners wash Toshiba RAS-3M31P2ACVG-SG indoor blowers?
Nightly bedroom use in humid flats calls for general servicing every three to four months, paired with annual chemical cleaning when airflow or drain flow slows. Clean evaporator fins preserve the 6.31 part-load COP rating.