Daikin RKM25PVMG holds NEA 5-tick listing MELS-DAI-AC150043 through 23 March 2027 at 2.51 kW capacity, 5.57 weighted COP, and 958 kWh annual test use. SP Group rates bring that yearly benchmark to S$299 versus S$259 on the printed label.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Review Daikin RKM25PVMG Rating and SP Group Cost
Registered under certificate MELS-DAI-AC150043 until 23 March 2027, Daikin RKM25PVMG earns 5 NEA ticks at 2.51 kW capacity. Rated efficiency hits 5.04 full load, 5.93 part load, and 5.57 weighted COP.
Official testing logs 958 kWh yearly energy draw, showing S$259 on the yellow NEA sticker. Using SP Group's 31.16 cents per kWh rate (GST included), that benchmark equals S$299 yearly or roughly S$25 monthly.
Full cooling pulls near 0.50 kW, while steady overnight modulation drops close to 0.21 kW. An 8-hour sleep shift uses around 2.0 to 2.6 kWh, costing S$19 to S$24 monthly.
Check RKM25PVMG Room Sizing and Efficiency Benchmarks
Match certified Daikin RKM25PVMG metrics against practical Singapore bedroom heat loads and active voucher rules:
Scroll to see more columns
| Ownership metric | Daikin RKM25PVMG value | Local operating note | Practical decision rule |
|---|---|---|---|
| NEA 5-tick listing | MELS-DAI-AC150043 | Expires 23 March 2027 | Verify active stock before ordering |
| Capacity and COP | 2.51 kW | 5.57 weighted COP | 5.04 full load; 5.93 part load | Suits 10 to 14 sqm rooms |
| Annual test energy | 958 kWh per year | S$259 label vs S$299 SP Group | About S$19 to S$24 per night shift |
| HDB voucher support | S$400 Climate Vouchers | Eligible 5-tick flat upgrades | Valid through end of 2027 |
Match Single Split Ledge Placement and Voucher Timing
Measured at 2.51 kW (about 8,560 BTU), RKM25PVMG cools enclosed HDB bedrooms, study corners, or helper rooms evenly. West-facing top floors still need blackout blinds so afternoon heat never forces nonstop compressor load.
Standalone outdoor units still require compliant HDB aircon ledge spacing and BCA stainless steel brackets. Confirm showroom stock still carries active registration MELS-DAI-AC150043 before March 2027 expiry, even though HDB vouchers remain open until year-end 2027.
Single-split buyers should also verify dedicated 13A or 15A isolator condition before delivery. Replacing aged trunking insulation at the same time prevents early pipe sweating inside warm utility corridors.
Schedule RKM25PVMG Servicing and Inspection Checks
Clean indoor coils protect that 5.93 part-load COP across humid months:
- Request a S$30 troubleshooting visit if airflow fades or water leaks appear. Proceeding with repairs or fresh installation waives that check fee, backed by 30-day cover.
- Solo bedroom splits receive standard quarterly cleaning for S$50 (14-day warranty). Adding a second unit sets fees at S$30 per unit, while three or more fall to S$25 per room.
- Stubborn dark mould clears through chemical washing booked at S$80 per single split (60-day warranty). Two-unit cleanings bill S$70 per unit, dropping to S$60 per split for three or more.
- Severe drain tray sludge needs full teardown cleaning priced at S$150 for one coil (90-day warranty). Pairing two coils bills S$125 apiece, while bookings of three or more run S$115 per coil.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Daikin · Cassette
Cassette not cooling: stuck gas-flow valve, not compressor
A flow-control valve stuck part-closed, restricting refrigerant to the indoor coil

Daikin · Ceiling-concealed
Daikin A3 with ceiling drip: drain pump motor failed
A condensate pump motor at the end of its working life, leaving the pan with no outlet
Common Questions
How much does a Daikin RKM25PVMG cost to run monthly in a Singapore bedroom?
Can HDB owners still use S$400 Climate Vouchers on Daikin RKM25PVMG?
Is 2.51 kW enough capacity for a condo master bedroom or open study?
How often should a Daikin RKM25PVMG single split receive servicing?
Sources
Sources checked 27 Nov 2026